Quadra-Fire GRAND-MBK-AU Installation Manual
Quadra-Fire GRAND-MBK-AU Installation Manual

Quadra-Fire GRAND-MBK-AU Installation Manual

Voyageur grand australian wood insert automatic combustion control (acc)
Hide thumbs Also See for GRAND-MBK-AU:

Advertisement

Quick Links

INSTALLER: Leave this manual with party responsible for use and operation.
OWNER: Retain this manual for future reference.
VOYAGEUR GRAND AUSTRALIAN
WOOD INSERT
AUTOMATIC COMBUSTION CONTROL
MODEL:
GRAND-MBK-AU
1
Installation Manual
Installation & Appliance Set-Up
NOTICE: DO NOT DISCARD THIS MANUAL
(ACC)
If the information in these instructions
is not followed exactly, a fire could result
causing property damage, personal injury,
or death.
Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any other
appliance.
Do not over fire - If appliance or chimney connector
glows, you are over firing. Over firing will void your
warranty.
Comply with all minimum clearances to combustibles
as specified. Failure to comply may cause house fire.
HOT SURFACES!
Glass and other surfaces are hot during
operation AND cool down.
Hot glass and appliance will cause burns.
Do not touch glass until it is cooled
Use leather gloves when reloading fuel
NEVER allow children to touch glass
Keep children away
CAREFULLY SUPERVISE children in same room as
appliance.
Alert children and adults to hazards of high
temperatures
High temperatures may ignite clothing or other
flammable materials.
Keep clothing, furniture, draperies and other
flammable materials away.
Fire Risk.
For use with solid wood fuel only.
Other fuels may over fire and generate poisonous
gases (i.e. carbon monoxide).
7075-177A
WARNING
WARNING
WARNING
17 August, 2018

Advertisement

Table of Contents
loading

Summary of Contents for Quadra-Fire GRAND-MBK-AU

  • Page 1 MODEL: • Do not over fire - If appliance or chimney connector glows, you are over firing. Over firing will void your GRAND-MBK-AU warranty. • Comply with all minimum clearances to combustibles as specified. Failure to comply may cause house fire.
  • Page 2: Table Of Contents

    N. Ovalizing Round Stainless Steel Liners ..17 O. Chimney Height / Rise and Run ....17 Quadra-Fire is a registered trademark of Hearth & Home Technologies. 7075-177A...
  • Page 3: Important Safety Information

    NOTE: Hearth & Home Technologies, manufacturer of this appliance, reserves the right to alter its products, their specifications and/or price without notice. The Quadra-Fire Voyageur Grand Australian Wood Insert is Hardwood Certified. Hardwood Particulate Emissions equaling 1.5 g/kg with a Space Heating Efficiency of 65%.
  • Page 4: Getting Started

    VOYAGEUR GRAND AU Install Guide Getting Started A. Design and Installation Considerations B. Fire Safety Consideration must be given to: To provide reasonable fire safety, the following should be • Safety given serious consideration: • Convenience 1. Install at least one smoke detector on each floor of •...
  • Page 5: Tools And Supplies Needed

    VOYAGEUR GRAND AU To minimize the effects of negative air pressure: E. Inspection of Appliance and Components • Install optional outside air kit with the intake facing • Remove appliance and components from packaging prevailing winds during the heating season and inspect for damage.
  • Page 6: Install Checklist

    VOYAGEUR GRAND AU G. Install Checklist ATTENTION INSTALLER: Follow this Standard Work Checklist This standard work checklist is to be used by the installer in conjuction with, not istead of, the instructions contained in this installation manual. _________________________________________________________________________________ Customer: ______________________________________________________________________________ Date Installe: ______________________________________________________________________________ Lot / Address:...
  • Page 7: Dimensions And Clearances

    VOYAGEUR GRAND AU Dimensions and Clearances NOTE: Flue Collar size is 152mm inside diameter (ID) A. Appliance Dimensions 830mm 830mm 828mm 602mm 602mm 603mm 459mm 459mm 456mm 127mm 124mm 124mm Figure 7.1 - Top View with Steel Surround Figure 7.4 - Top View with Cast Surround 1092mm 787mm 1118mm...
  • Page 8 VOYAGEUR GRAND AU 353in 357mm 357mm 15° 15° 15° 613mm 613mm 597mm 597mm 597mm 613mm 154mm 154mm 154mm 73mm 73mm 73mm Figure 8.1 - Side View with Steel Surround Figure 8.4 - Side View with Cast Surround 382mm 385mm 385mm 30°...
  • Page 9: Clearances To Combustibles

    VOYAGEUR GRAND AU B. Clearances to Combustibles, TOP TRIM (19mm max depth) 896mm 572mm 1092mm Minimum Opening Dimensions Millimeters Height Front Width (Steel Surround) HEARTH EXTENSION (MINIMUM REQUIREMENT)* Front Width (Cast Surround) 1176mm Back Width Figure 9.1 Depth (Steel Surround) Depth NOTE: If trim measurement is over 19mm in depth use (Cast Surround)
  • Page 10 The R value of a material must be equal or larger then the required R value to be acceptable. Quadra-Fire Voyageur Grand ACC does not require a insulating Floor Protector, as they are tested and comply with the minimum Floor Protector requirements of AS/ NZS 2918:2001.
  • Page 11: Chimney Systems

    VOYAGEUR GRAND AU Chimney Systems A. Locating Your Appliance & Chimney • Consider the appliance location in order to avoid floor and ceiling attic joists and rafters. Location of the appliance and chimney will affect • Locate termination cap away from trees, adjacent performance.
  • Page 12: Minimum Height Of Flue System Exit

    VOYAGEUR GRAND AU B. Minimum Height of Flue System Exit 3000mm more than 3000mm or less 600mm 3000mm minimum 3000mm increase from 1000mm minimum until clear within 3000mm of flue top increase as necessary until nothing within 3000mm of fluetop any nearby structure Figure 12.1 NOTICE:...
  • Page 13: Venting Systems

    VOYAGEUR GRAND AU D. Venting Systems Chimney Connector: It is also known as flue pipe or stove pipe. It must be 152mm minimum diameter stainless steel connector pipe. Chimney: The chimney can be new or existing, masonry or prefabricated and must meet the following minimum requirements as specified below.
  • Page 14: Masonry Chimney

    VOYAGEUR GRAND AU G. Masonry Chimney • Must have at least 16mm fire clay lining joined with refractory cement. NOTE: Installations into a clay flue without a stainless steel liner may reduce draw which affects performance, will cause the glass to darken and produce excessive creosote and create start-up issues. •...
  • Page 15: Prefabricated Metal Chimney

    VOYAGEUR GRAND AU H. Prefabricated Metal Chimney NOTE: Refer to chimney liner manufacturer for The chimney can be new or existing, masonry or recommendations on supporting the liner. prefabricated and must meet the following minimum Installation into fireplaces without a permit will requirements: void the listing.
  • Page 16: Install Into A Masonry Fireplace

    VOYAGEUR GRAND AU I. Install into a Masonry Fireplace K. Securing Chimney Components The insert must be installed as per the requirements of All joints should be secured with 3 sheet metal screws or your local inspection authority. It is recommended to use rivets per pipe manufacturers instructions.
  • Page 17: Zero-Clearance Fireplace

    O. Chimney Height / Rise and Run or flaws such as burnouts, metal or refectory warping. To be sure that your Quadra-Fire insert burns properly, the chimney draft (static pressure) should be approximately Inspection to a minimum of NFPA 211 Level II is -2.54mm water column (W.C.) during a high burn and...
  • Page 18: Appliance Set-Up

    VOYAGEUR GRAND AU Appliance Set-Up A. Outside Air Kit Installation A source of air (oxygen) is necessary in order for combustion to take place. Whatever combustion air is consumed by the fire must be replaced. Air is replaced via air leakage around windows and under doors. In homes that have tightly sealed doors and windows, an outside air Grille hinges source is needed.
  • Page 19: Optional Offset Adapter Installation

    If the seal is questionable use high temperature local Simpson Duravent Pipe Distributor or from your local sealant such as stove mastic (Figure 19.2). Quadra-Fire dealer, Part Number DV-6DLR-E15ADSS. 2. Attach gasket to bottom side of flue collar with a thin coat of silicone.
  • Page 20: Securing Appliance To Stove Pipe/Liner

    VOYAGEUR GRAND AU E. Securing Appliance to Stove Pipe/Liner F. Surround & Trim Kit Installation 1. Once you have the appliance in place and secured, Standard Size: 109.22cm W x 78.74cm H reach up through the flue opening and grab the Large Size: 129.54cm W x 86.36cm H attachment bar and pull down inside flue opening 1.
  • Page 21: Standard Surround & Cast Trim Kit

    VOYAGEUR GRAND AU 7. Place the cast footers under the metal sides aligning G. Standard Surround & Cast Trim Kit the top and bottom holes in the cast footers and metal Standard Size: 184.15cm W x 76.2cm H sides. Large Size: 121.92cm W x 34 86.36cm H 8.
  • Page 22: All Cast Surround Kit

    VOYAGEUR GRAND AU H. All Cast Surround Kit I. Blower Cord Installation on Left Side Size: 111.76cm W x 83.82cm H The blower cord is shipped to be installed on the right side Included in Surround Kit: (2) side pieces, left and right; of the appliance.
  • Page 23 VOYAGEUR GRAND AU 4. Remove the 2 screws at the top of the control plate. 7. Use needle nose pliers to remove the strain relief that Push the bottom of the control plate to the inside of protects the power cord from the control plate. the appliance and partially remove the control plate assembly.
  • Page 24 VOYAGEUR GRAND AU Strain Relief 10. Replace the strain relief on the power cord in the same position as before. Locate the indentation on the cord made by the strain relief. Once replaced, push the strain relief back into the control plate. 12.
  • Page 25 VOYAGEUR GRAND AU Placement Slot Blower Access Assembly Grille hinges Hold Down downward Bracket Remove Screws & Pull Access Assembly Remove Screws from Hold away from Insert Down Bracket and Pull Forward Figure 25.1 17 August, 2018 7075-177A...
  • Page 26: Accessory List

    VOYAGEUR GRAND AU Accessory List A. Accessory List GRAND-MBK-AU Service Parts Beginning Manufacturing Date: April 2013 Ending Manufacturing Date: Active #25 Cast Surround Assemblies 25.3 25.2 25.1 25.4 25.5 IMPORTANT: THIS IS DATED INFORMATION. Parts must be ordered from a dealer or distributor.
  • Page 27 VOYAGEUR GRAND AU GRAND-MBK-AU Service Parts Beginning Manufacturing Date: April 2013 Ending Manufacturing Date: Active #26 Metal Surround Assemblies 26.3 26.2 26.1 26.4 26.5 IMPORTANT: THIS IS DATED INFORMATION. Parts must be ordered from a dealer or distributor. Stocked Hearth and Home Technologies does not sell directly to consumers. Provide model number and serial number when requesting service parts from your dealer or distributor.
  • Page 28 Hearth & Home Technologies 352 Mountain House Road Halifax, PA 17032 Division of HNI INDUSTRIES Please contact your Quadra-Fire dealer with any questions or concerns. For the number of your nearest Quadra-Fire dealer log onto www.quadrafire.com CAUTION DO NOT DISCARD THIS MANUAL...

Table of Contents