T8611G CHRONOTHERM
NO
Wallplate Installation
The thermostat can be mounted horizontally on the wall or on
a 2 in. x 4 in. wiring box. Position wallplate horizontally on the
wall or on a 2 in. x 4 in. wiring box.
1. Position and level the wallplate (for appearance only).
The thermostat will function properly even when not
level.
2. Use a pencil to mark the mounting holes. See Fig. 3.
WIRES
THROUGH WALL
WALL
ANCHORS
(2)
Fig. 3. Mounting the wallplate.
68-0165—1
®
IV DELUXE PROGRAMMABLE HEAT PUMP THERMOSTAT
NO
Fig. 2. Typical location of thermostat.
WALL
MOUNTING
HOLES
MOUNTING
SCREWS
M10822
YES
NO
5 FEET
[1.5 METERS]
3. Remove the wallplate from the wall and drill two 3/16
inch holes in the wall (if drywall) as marked. For firmer
material such as plaster, drill two 7/32 inch holes.
Gently tap anchors (provided) into the drilled holes until
flush with the wall.
4. Position the wallplate over the holes, pulling wires
through the wiring opening.
5. Loosely insert the mounting screws into the holes.
6. Tighten mounting screws.

WIRING

All wiring must comply with local electrical codes and
ordinances. Follow equipment manufacturer wiring
instructions when available. Refer to Fig. 15 and 16 for typical
hookups. A letter code is located near each terminal for
identification. Refer to Table 4 for terminal designations.