Refer to Table 14 for thermostat cross referencing information.
Model
Number
T8611G
Two-stage heat and one-stage cool heat pump thermostat; powered direct from 24 Vac
transformer; automatic changeover; system switch—EM HEAT-HEAT-OFF-COOL-AUTO; fan
switch—ON-AUTO; O/B or O and B terminals
T8611G1004
TRADELINE® thermostat; Honeywell
logo.
T8611G1012
Canadian TRADELINE® thermostat;
Honeywell logo; degree C.
T8611G1020
Heil Quaker; part no. HQ713669HW.
T8611G1038
Trane; part no. THT-0603; ordering no.
X13510323-13-7.
T8611G1046
Carrier; part no. HH07AE001.
T8611G1053
Lennox; part no. 27H3001.
T8611G1095
Trol-A-Temp® by Honeywell thermostat.
T8611G1103
TRADELINE® thermostat; Honeywell
logo; Premier White® color.
T8611G1111
Trane; Premier White® color;
part no. TAYSTAT501.
T8611G1145
Canadian TRADELINE® thermostat;
Honeywell logo; Premier White® color;
degree C.
T8611G1152
Solitare logo; Premier White® color;
Nordyne part no. 9132410.
T8611G1178
Canadian Carrier; Premier White® color;
degree C; part no. HH07AE001C-W.
T8611R
Two-stage heat and one-stage cool heat pump thermostat; powered direct from 24 Vac
transformer; system switch—EM HEAT-HEAT-OFF-COOL; fan switch—ON-AUTO;
O/B or O and B terminals
T8611R1000
TRADELINE® thermostat;
Honeywell logo.
T8611R1018
York; part no. 025-27655.
T8611R1034
Rheem; Honeywell logo; part no.
41-21594-05.
T8611R1042
Canadian TRADELINE® thermostat;
Honeywell logo; degree C.
T8611R1059
Coleman; part no. 3600A381.
a Contact Trol-A-Temp ® for thermostat.
T8611G CHRONOTHERM
Table 14. Thermostat Cross Reference Information.
Description
®
IV DELUXE PROGRAMMABLE HEAT PUMP THERMOSTAT
TRADELINE®
Replacement
T8611G2002
Configure changeover in Installer Setup 12
and O/B terminal in 29; jumper Y1 to W1.
T8611G2002
Configure changeover in Installer Setup 12,
°C in 14 and O/B terminal in 29; jumper Y1
to W1.
T8611G2002
Configure changeover in Installer Setup 12
and O/B terminal in 29; jumper Y1 to W1.
T8611G2002
Configure changeover in Installer Setup 12
and O/B terminal in 29; jumper Y1 to W1.
T8611G2002
Configure changeover in Installer Setup 12
and O/B terminal to O in 29; jumper Y1
to W1.
T8611G2002
Configure changeover in Installer Setup 12
and O/B terminal in 29; jumper Y1 to W1.
a
T8611G2051
O and B terminals are not used.
T8611G2002
Configure changeover in Installer Setup 12
and O/B terminal in 29; jumper Y1 to W1;
taupe color.
T8611G2002
Wiring differences (old=new): F=L, B=C;
configure changeover in Installer Setup 12
and O/B terminal to O in 29; taupe color.
T8611G2002
Configure changeover in Installer Setup 12,
°C in 14 and O/B terminal in 29; jumper Y1
to W1; taupe color.
T8611G2002
Configure changeover in Installer Setup 12
and O/B terminal in 29; jumper Y1 to W1;
taupe color.
T8611G2002
Configure changeover in Installer Setup 12,
°C in 14 and O/B terminal in 29; jumper Y1
to W1; taupe color.
T8611G2002
Configure O/B terminal in Installer
Setup 29; no P terminal.
T8611G2002
Wiring differences (old=new): B=C, H=B,
X=L; configure O/B terminal in Installer
Setup 29.
T8611G2002
Configure O/B terminal in Installer
Setup 29; no P terminal.
T8611G2002
Configure O/B terminal in Installer Setup 29
and °C in 14; no P terminal; taupe color.
T8611G2002
Configure O/B terminal in Installer
Setup 29; no P terminal.
21
Remarks
(continued)
68-0165—1