Installer Setup - Honeywell T8611G Chronotherm IV Deluxe Manual

Programmable heat pump thermostat
Table of Contents

Advertisement

System and Fan Settings
The system default setting is Heat and the fan default setting
is Auto. Use the System and Fan keys or switches to change
the settings. See Fig. 8. The fan settings can be set for each
program period individually. The system selection is for all the
program periods.
System settings control the thermostat operation as follows:
Em Heat: Emergency heat output is controlled as Stage 1
heat. Cooling system is off. Compressor is de-
energized.
Heat: The thermostat controls the heating.
Off: Both the heating and cooling are off.
Cool: The thermostat controls the cooling.
Auto: The thermostat automatically changes between
heating and cooling operation, depending on the indoor
temperature.
Fan settings control the system fan as follows:
On: Fan operates continuously.
Auto: Fan operates with equipment.
Time
Run
Set Current
Wake
Program
Day/Time
Heat/Cool
Hold Temp
Day
Settings
Daylight
Copy
Time
Fig. 8. T8611G System and Fan key locations.
NOTE: Always press the keys with your fingertip or similar
blunt tool. Sharp instruments like a pen or pencil
point can damage the keyboard.
Temperature Settings
Refer to Table 5 for the default program. If the daytime energy
savings period is not used, press the period key (Leave or
Return) until the time is blank. The fan setting feature is
available on select thermostat models. See Programming
Section for complete instructions on changing the program.
Table 5. Default Program Settings.
Heat
Period
Time
Setpoint
Wake
6:00 AM
70°F (21°C)
Leave
8:00 AM
62°F (16.5°C) 85°F (29.5°C)
Return
6:00 PM
70°F (21°C)
Sleep
10:00 PM 62°F (16.5°C)
T8611G CHRONOTHERM
Set Program
Leave
Return
Sleep
System
System
Fan
Fan
M15042
Cool
Fan
Setpoint
Setting
78°F (25.5°C)
Auto
Auto
78°F (25.5°C)
Auto
82°F (28°C)
Auto
®
IV DELUXE PROGRAMMABLE HEAT PUMP THERMOSTAT

INSTALLER SETUP

NOTE: For most applications, the thermostat factory
settings will not need to be changed. Review the
factory settings in Table 6 and if no changes are
necessary, go to the Installer System Test section.
The Installer Setup is used to customize the thermostat to
specific systems. Some of the options include temperature
display, changeover and outdoor temperature display. Installer
Setup numbers are listed in Table 6. The table includes all the
configuration options and the factory settings for the
thermostat.
A combination of key presses are required to use the Installer
Setup feature.
— To enter the Installer Setup, press and hold the Information
i key with the increase
first number is displayed. All display segments appear for
approximately three seconds before the number is
displayed. See Fig. 9 and 10.
— To advance to the next Installer Setup, press the Time
key.
— To change a setting, use the increase
key.
— To scroll the Installer Setup numbers backwards, press the
Time
key.
— To exit the Installer Setup, press Run Program.
Set Program
Start Time
Hold for
Em Ht
Aux Ht
Mon
TueWedThuFriSatSun
Wake
LeaveReturnSleep
System
Em Heat
Off
Cool
Fig. 9. Display of all the segments of the LCD.
INSTALLER SETUP
NUMBER DISPLAY
(COLUMN 2
OF TABLE 6)
Fig. 10. Display of Installer Setup number and setting.
7
and decrease
keys until the
or decrease
Temporary Setting Enrg
Set Day/Time
AM
Room
PM
%Humid
Heat
Cool
Outdoor
In
Recovery
Auto
Repl Batt
DST
Fan
Auto
Wait
On
FACTORY SETTING
OR OTHER CHOICE
DISPLAY (COLUMN 3
OR 5 OF TABLE 6)
68-0165—1
Sav
Auto
M10345
M10404

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents