Alternate Wiring

If labels do not match letters on the thermostat, check
the chart below and connect to terminal as shown here
(see notes, below).
B
If wires will be connected to both
terminals, remove metal jumper (see page 6).
Do not use
electrical tape.
If you have a heat pump without auxiliary/backup
heat connect O or B, not both. If you do not have
a heat pump, do not connect B. Wrap bare end of
wire with electrical tape.
Place a jumper (piece of wire) between Y and W if
you are using a heat pump without auxiliary/backup
heat.
Thermostat does not work on Heat Pumps with auxiliary/
backup heat.