Accentronix CELLSWITCH 100 User Manual page 13

Table of Contents

Advertisement

User Manual for Cellswitch 100
STEP 2 – Program the desired security settings.
SECURITY
1234.F4a"0827727789;0825091827;"
1234.F4b"0827727789;0825091827;"
1234.F4on
1234.F4off
1234.F5a"5678"
F5b reserved for SIM PIN
Add security numbers
When the unit is used for access or remote control. Only
these cellphone numbers will be accepted by the unit when it
is called. Note the semicolon at the end of each number.
Up to 8 numbers may be added in one SMS.
Delete a security number.
Remove the programmed security numbers using this command.
Note the semicolon at the end of each number.
Up to 8 numbers may be removed in one SMS.
Enable security
The relay output will only switch when a programmed security
number calls the device.
Disable security (Default)
The relay output will switch when any cellphone number calls
the device.
SMS programming password (Default: 1234)
Changes the default SMS password from 1234 to 5678.