Sulzer S10 - PE125 Installation, Operating And Maintenance Instructions

Sulzer S10 - PE125 Installation, Operating And Maintenance Instructions

Submersible grinder pump

Advertisement

Submersible Grinder Pump Type ABS Piranha S10 - PE125
Installation, Operating and Maintenance Instructions
EN
www.sulzer.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the S10 - PE125 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Sulzer S10 - PE125

  • Page 1 Submersible Grinder Pump Type ABS Piranha S10 - PE125 Installation, Operating and Maintenance Instructions www.sulzer.com...
  • Page 2: Table Of Contents

    Bearings and Mechanical Seals ..........................14 10.6 Maintenance of Lifting Stations in accordance with EN 12056.................. 14 10.7 Cleaning ..................................14 10.8 Venting of the volute ..............................15 Troubleshooting Guide �������������������������������������������������������������������������������������������������������������������������������������������� 15 Sulzer reserves the right to alter specifications due to technical developments!
  • Page 3: Application Areas

    The general and specific health and safety requirements are described in detail in the “Safety Instructions for Sulzer Products Type ABS” booklet. If anything is not clear or you have any questions as to safety make certain to contact the manufacturer Sulzer.
  • Page 4: Technical Data

    Detailed technical information is available in the technical data sheet Sulzer Piranha submersible grinder pump 08 - 125 which can be downloaded from www.sulzer.com > Products & Services > Pumps and Systems. Maximum noise level ≤ 70dB. This may be exceeded in certain circumstances.
  • Page 5: General Design Features

    Installation, Operating and Maintenance Instructions (Original Instructions) Submersible Grinder Pump Type ABS Piranha S10 - PE125 General design features Submersible grinder pump fitted with a shredding system hydraulic. The shredding system is located before the impeller and consists of a shredding rotor in combination with a stationary cutting ring fixed to a spiral bottom plate.
  • Page 6: Design Features Piranha-Pe

    Installation, Operating and Maintenance Instructions (Original Instructions) Submersible Grinder Pump Type ABS Piranha S10 - PE125 4�2 Design features Piranha-PE Submersible grinder pump fitted with a shredding system hydraulic and a Premium Efficiency motor. Pressure release screw Upper bearing - single row...
  • Page 7: Weights

    Weight per metre (kg) 0.43 0.63 1.10 1.75 2.95 Weights of accessories, other than or in addition to those listed, must also be included when specifying the working load of any lifting equipment. Please consult with your local Sulzer representative prior to installation.
  • Page 8: Transport And Storage

    Installation, Operating and Maintenance Instructions (Original Instructions) Submersible Grinder Pump Type ABS Piranha S10 - PE125 Transport and storage 6�1 Transport During transport, care should be taken that the pump is not dropped or thrown. The unit is fitted with a lifting device to which a chain and shackle may be attached for transport purposes.
  • Page 9: Mounting And Installation

    Installation, Operating and Maintenance Instructions (Original Instructions) Submersible Grinder Pump Type ABS Piranha S10 - PE125 Mounting and installation The regulations covering the use of pumps in sewage applications together with all regulations involving the use of explosion-proof motors should be observed.The cable ducting to the control panel should be sealed off in a gas-tight manner by the use of a foaming material after the cable and control circuits have been pulled through.
  • Page 10: Electrical Connection

    Installation, Operating and Maintenance Instructions (Original Instructions) Submersible Grinder Pump Type ABS Piranha S10 - PE125 Electrical connection Before commissioning an expert should check that one of the necessary electrical protective devices is available. Earthing, neutral, earth leakage circuit breakers, etc. must comply with the regulations of the local electricity supply authority and a qualified person should check that these are in perfect order.
  • Page 11: Wiring Diagrams

    Installation, Operating and Maintenance Instructions (Original Instructions) Submersible Grinder Pump Type ABS Piranha S10 - PE125 8�3 Wiring diagrams Single phase: NOTE: 60 Hz: R S C R = Run 50 Hz: R C S 50 Hz: F1 FO F1 FO...
  • Page 12: Checking Direction Of Rotation

    Installation, Operating and Maintenance Instructions (Original Instructions) Submersible Grinder Pump Type ABS Piranha S10 - PE125 8�4 Checking direction of rotation When three phase units are being commissioned for the first time and also when used on a new site, the direction of rotation must be carefully checked by a qualified person.
  • Page 13: Maintenance And Service

    When carrying out repairs, only original spare parts supplied by the manufacturer should be used. Sulzer warranty conditions are only valid provided that any repair work has been carried out in an Sulzer appro- ved workshop and where original Sulzer spare parts have been used.
  • Page 14: 10.4 Oil-Fill Quantities

    Installation, Operating and Maintenance Instructions (Original Instructions) Submersible Grinder Pump Type ABS Piranha S10 - PE125 10.3.1 Instructions on how to drain and fill the oil chamber 1. Loosen the plug screw enough to release any pressure that may have built-up, and re-tighten (for location see pages 5 and 6).
  • Page 15: Venting Of The Volute

    Installation, Operating and Maintenance Instructions (Original Instructions) Submersible Grinder Pump Type ABS Piranha S10 - PE125 10�8 Venting of the volute After lowering the pump into a sump full of water, an air lock may occur in the volute and cause pumping problems.
  • Page 16 SERVICE LOG Date Hours of Comments Sign Operation...
  • Page 17: Service Log

    SERVICE LOG Date Hours of Comments Sign Operation...
  • Page 18 SERVICE LOG Date Hours of Comments Sign Operation...
  • Page 19 SERVICE LOG Date Hours of Comments Sign Operation...
  • Page 20 Sulzer Pump Solutions Ireland Ltd. Clonard Road, Wexford, Ireland Tel. +353 53 91 63 200 Fax +353 53 91 42335. www.sulzer.com...

Table of Contents