– As soon as the emergency start lever is in the
starting position, the electric starter or recoil
starter can be used; Chapter 4.2.2 and 4.2.3.
The oil level must always be checked before an
emergency start, as insufficient oil pressure
can lead to complete damage of the engine
within a very short time.
After this, the engine can only be
stopped with the starting key in the
emergency operating mode if the emergency
starting lever is first turned back clockwise to
the stop position.
Immediately after a period of emergency
running, ascertain the cause of the fault and
have it rectified; Chapter 6.
Have the emergency-starting lever sealed once
again by a HATZ service point.
When the automatic electrical shutdown system
is used, the emergency start described above
means that liability for risks must be accepted
by the operator (Motorenfabrik HATZ assumes
no liability) !
In case of difficulty contact the nearest HATZ
service point.
Automatic electrical shutdown system
(additional equipment)
This is characterized by a brief flashing of all
pilot lamps once the starter key has been turned
to position I (Fig. 15).
Important !
If the engine cuts out immediately after starting
or switches off by itself during operation, a
monitoring element in the automatic shutdown
system has tripped. The corresponding indicator
light (Fig. 14, positions 2 - 4) will come on.
After the engine has stopped, the display contin-
ues to glow for about 2 minutes.
The electrical device then switches itself off au-
tomatically.
The display lights up again after the start key
has been turned back to position 0 and then to
position I again.
Trace and eliminate the cause of the operating
fault before trying to restart the engine
(see chapter 6.2.).
The display light goes out when the engine is
next started.
Even with automatic shutdown monitoring
the oil level must be checked every 8 – 15
operating hours (Chapter 5.2.1.).
4.3.

Stopping the engine

17
– Move the speed adjustment lever „1" back
to the STOP position. The engine cuts out.