Hatz Diesel 1B20V Original Instruction Book page 31

Hide thumbs Also See for 1B20V:
Table of Contents

Advertisement

Malfunctions
Possible causes
At low
Starting speed below 400 rpm:
temperatures
- Viscosity of oil too high.
- Battery charge too low.
If equipped with a
Solenoid faulty and/or fault in
stop solenoid or
the electrical system.
automatic electri-
cal shutdown sys-
tem (additional
equipment)
6.2.
Speed control lever not moved
Engine fires but
far enough towards „START".
does not run.
Equipment not disengaged.
Fuel filter blocked.
With automatic
One of the automatic shut-
shutdown
down's monitoring elements
(optional extra)
has initiated a stop signal.
(See also Chapter 6.4.).
6.3.
Fault in the electrical system:
Starter motor does
- Battery and/or other cables
not operate or
incorrectly connected up.
engine does not
- Cable connections loose
turn over.
and/or oxidised.
- Battery faulty and/or flat.
- Starter motor faulty.
- Faulty relays, monitoring
element.
Remedy
Change lubricating oil and add
oil of the correct viscosity class.
Check the battery, if necessary
contact a service station.
See workshop manual.
Move lever to „START" position.
Disengage engine from equip-
ment if possible.
Renew fuel filter.
Localise the monitoring element
responsible and clear the fault,
or contact a HATZ service
station.
Check electrical system and its
component.
See also the workshop manual.
29
Chap.
5.3.1.
4.1.1.
7.
4.2.1.
5.4.1.
7.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

1b40w1b50v1b50w1b30v1b40v