FIFOTRACK A300 User Manual page 15

Vehicle gps tracker
Table of Contents

Advertisement

A300 USER GUIDE
I/O
Color
VCC
Red
GND
Black
IN1
White
IN2
White
IN3
White
IN4
White
OUT1
Yellow
OUT2
Yellow
AD1
Blue
AD2
Blue
PLS
Brown
GND
Black
DC5V
Orange
iBtn
Purple
Copyright © fifotrack 2015 All rights reserved
Function
Positive power, connect to positive of vehicle battery, input voltage
range 11-36V
Ground, connect to negative of vehicle battery or the vehicle's iron
part.
Digital input1, negative input (default SOS button)
Digital input2, positive input, default connect to ACC for status
detection.
Digital input3, custom input, default positive.
Digital input4, custom input, default negative.
Output1
Output active: low level (0V)
Output inactive: open drain (OD)
Max open-drain (inactive) voltage: 45V
Max current for output low voltage (valid): 500mA
Output2
Output active: low level (0V)
Output inactive: open drain (OD)
Max open-drain (inactive) voltage: 45V
Max current for output low voltage (valid): 500mA
12 bits analog input, supports voltage range 0-30V. Connect to
external sensor, eg, fuel sensor.
12 bits analog input, supports voltage range 0-30V. Connect to
external sensor, eg, fuel sensor.
Impulse detection, 0~100kHz
1-Wire protocol port for i-Button or temperature sensor