The Code Modules fields are:
Field
Boot Code
Version
Digital Secure
Processor
Downloadable
Object
Information Table
Object
Ver
Status
Description
The boot code version in ASCII format
The firmware version and build date in ASCII format
The digital secure processor version in ASCII format
Lists all objects loaded, or being loaded, onto the DCT3080
in ASCII format. The information displayed for each object
depends on the running environment. If a download is not
in progress, the LED displays the current environment
running and version number, as shown in Figure 4-9. On
the LED, "bPC" represents base platform or Thin Client
code.
The object name
The object version
The object status, updated on the OSD and LED every
5 seconds while you display the diagnostic:
OSD
MEM ALLOC
LOADING
STARTING
ENABLED
ENA–NOT
RUN
STOPPING
DISABLED
DIS-NOT
RUN
DCT3080 Installation Manual
Status
Allocated
Loading
Enabling
Enabled
Enabled_Not_
Runnable
Disabling
Disabled
Disabled_Not_
Runnable
61
Description
Memory for object is
allocated
Object is being loaded
Object is being started
(the constructor is
running)
Object is running
Object is enabled, but
cannot run
Object is being stopped
(the destructor is running)
Object has been disabled
Object is disabled and
cannot run