  • Page 1: Introduction

    INDUSTRIAL PORTABLE INSTALLATION AND OPERATORS MANUAL WC5000H/E WINCO INC. 225 S. CORDOVA AVE. LE CENTER, MN 56057 507-357-6821 SERVICE DEPT. 507-357-6831 wincogen.com...
  • Page 2: Table Of Contents

    Should you experience a problem please follow the “Troubleshooting Tables” near the end of this MODEL ___________________________ manual. The warranty listed in the manual describes what you can expect from WINCO should you need SERIAL NUMBER_________________________ service assistance in the future. PURCHASE DATE_________________________ TABLE OF CONTENTS...
  • Page 3: Safety Information

    b. Keep fuel containers out of reach of children. SAFETY INFORMATION c. Do not smoke or use open fl ame near the generator set or fuel tank. This engine generator set has been designed and d. Keep a fi re extinguisher nearby and know its manufactured to allow safe, reliable performance.
  • Page 4: Unit Capabilities

    TESTING POLICY UNIT CAPABILITIES Before any generator is shipped from the factory, it GENERATOR CONNECTIONS is fully checked for performance. The generator is loaded to its full capacity, and the voltage, current WC5000 - This generator is equipped with Switch- and frequency are carefully checked.
  • Page 5: Preparing The Unit

    1. This generator-set was in good order when much starting current as running current. Repulsion shipped. Inspect the generator-set promptly after Induction motors are the easiest to start and require receiving it. If any damage is noted, notify the trans- only 1 1/2 to 2 1/2 times as much starting as running portation company immediately;...
  • Page 6: Oil Alert System

    OIL ALERT SYSTEM AMBIENT TEMPERATURE This WINCO Industrial generator is equipped with a SAE 10W-30 is recommended for general use. Other viscosities shown in the chart may be used when the average temperature in low oil shutdown system. This engine uses a fl oat your area is within the indicated range.
  • Page 7: Initial Start Up

    ® The automatic Conserv-R control consists of a BASIC OPERATION solid state module mounted in the generator recep- START tacle box, a switch, resistor and an electromagnet MANUAL STARTING mounted on the engine near the throttle lever. The ® automatic Conserv-R control is only offered as a Refer to the engine manual for additional starting, factory installed feature.
  • Page 8: Stopping & Storage

    Note: Running the engine to use up the fuel in the 6. When the engine starts, open the choke lines and carburetor will still leave a small amount of gradually. fuel in the carburetor. It is best for extended storage 7.
  • Page 9: Connecting The Loads

    These engine-generator sets are inherently self reg- The speed of the engine was carefully adjusted at ulating based on engine speed. The engine governor the factory so that the generator produces the proper will automatically adjust itself to the load. No harm voltage and frequency.
  • Page 10: Engine Care

    1. These engine generator sets are designed for MAINTENANCE SCHEDULE portable heavy duty commercial use. Receptacles Every 3 Every 6 Every Refer are provided on the control panel to permit 120 and REGULAR SERVICE PERIOD (3) Each First Perform at every Month Months Months...
  • Page 11: Generator Care

    2. Checking the Oil Level: The oil level must al- 4. Spark Plug: Replace annually or every 300 hours of operation. Always replace with the same ways be checked before the engine is started. Take care to remove any dirt or debris from around the spark plug that came in the engine and check gap oil fi...
  • Page 12: Specifications

    ——————————————————————— engine cooling fi ns and fl ywheel. Clean more often SPECIFICATIONS if necessary. Failure to keep these areas clean may cause overheating and permanent damage to the WC5000H/E unit. Generator manufacturer WINCO Inc Part number 15041-005 2.
  • Page 13: Control Panel Wiring Diagram

    5070-00 60706-242...
  • Page 14: Warranty Information

    To the extent permitted by law, any and all warranties, including those of merchantability and fi tness for a particular purpose, are limited to 24 months from date of purchase. In no event is WINCO liable for incidental or consequential damages.
  • Page 15: Warranty Statement

    WINCO cannot deny warranty solely for lack of receipts. As the generator owner, you should be aware that WINCO may deny you warranty coverage if your generator or a part has failed due to abuse, neglect, or improper maintenance or unapproved modifi ca- tions.