iDRAC Settings utility

The iDRAC settings utility is an interface to set up and configure the BMC parameters by using UEFI. You
can enable or disable various BMC parameters by using the iDRAC settings utility. For more information
about using BMC, see Integrated Dell Remote Access Controller 8 User's Guide at Dell.com/
idracmanuals.

Entering the iDRAC settings utility

1.
Turn on or restart the managed system.
2.
Press F2 during Power-on Self-test (POST).
3.
On the System Setup Main Menu page, click iDRAC Settings.
The iDRAC Settings screen is displayed.

Changing the thermal settings

The iDRAC Settings utility enables you to select and customize the thermal control settings for your
system.
1.
Enter the iDRAC Settings utility.
2.
Under iDRAC Settings → Thermal → User Option, select one of the following options:
Default
Maximum Exhaust Temperature
Fan Speed Offset
NOTE: When the User Option is set to the default Auto setting, the user option cannot be
modified.
3.
Set the Maximum Air Exhaust Temperature or the Fan Speed Offset fields.
4.
Click Back → Finish → Yes.