DSC PC5020 Power864 Installation Manual page 68

Hide thumbs Also See for PC5020 Power864:
Table of Contents

Advertisement

Module
Compatible?
Classic Escort (VPM-1)
DLM-1
DLM-4 v1.x
DLM-4 v1.0L
DLM-7
Escort5580 v3.0
LCD5500 v1.X
LCD5500Z v2.X
LCD5501Z v1.x
LCD5500Z v3.X
LCD5501Z v2.x
LCD5501Z32-433
LCD600
LED615
Links1000 v3.0
Links2150 v1.3W
Links2450 v1.3
PC-16 Out
PC5100
PC5108 v1.X
PC5108L
PC5108 v2.x
PC5132 v1.X
PC5132 v2.X
PC5132 v3.X
PC5200
PC5204
PC5208
PC5320
PC5400 Printer/DVACS
Module v1.X to v2.1
PC5400 Printer/DVACS
Module v2.2
PC55XX
PC55XXZ
PC5506
PC5509
PC5700 v1.X
PC5700 v2.0
PC5720
PC5908
PC5928
PC5936
Skyroute v2.2
SL-XX
T-Link
©2002 Digital Security Controls Ltd.
Toronto, Canada • www.dsc.com
Technical Support: 1-800-387-3630
Printed in Canada 29005907 R004
PC5020 Module Compatibility
Comments
No
No
No
Yes
No
Yes
Fully compatible with Power864.
Yes
No Keypad zone support. Some display messages not supported. Can
only be used on Partition 1 and Partition 2, and the first 32 zones.
Yes
Can only be used on Partition 1 and Partition 2, and the first 32 zones.
Yes
Can only be used on Partition 1 and Partition 2, and the first 32 zones.
Yes
Fully compatible with Power864.
Yes
Fully compatible with Power864.
Yes
Fully compatible with Power864.
No
No
Yes
Yes
Some events not supported (reporting zones 33-64 and partions 3-8).
Yes
Some events not supported (reporting zones 33-64 and partions 3-8).
No
Yes
Can only add addressable devices to the first 32 zones.
Yes
Can only support the first 32 zones. Enrolls as two expander modules -
each module will use up two supervisory slots.
Yes
Can only be assigned zones from 9 to 32. Will not support zones 33 to
64. Camera scripts can only be run for zones 9 to 32. Enrolls as two
expander modules and uses two supervisory slots.
Yes
Fully compatible with Power864.
Yes
No support for Wireless Keys, Pendants or Handheld Keypads. Only the
first 32 zones can be used as wireless zones.
Yes
No identified Wireless Keys support. Only the first 32 zones can be
used as wireless zones.
Yes
Only the first 32 zones can be used as wireless zones.
Yes
Fully compatible with Power864.
Yes
Fully compatible with Power864.
Yes
Fully compatible with Power864.
Yes
Fully compatible with Power864.
Yes
Some printing messages not supported. Some events not supported.
Yes
Some events not supported.
Yes
No Keypad zone support. Can only be used on Partition 1 and Partition
2, and the first 8, 16, or 32 zones.
Yes
Can only be used on Partition 1 and Partition 2, and the first 8, 16, or
32 zones.
No
No
Yes
Enrolls as two expander modules - each module will use up two super-
visory slots.
Yes
Fully compatible with Power864.
Yes
Enrolls as two expander modules - each module will use up two super-
visory slots.
No
No
Yes
Fully compatible with Power864.
Yes
Some events not supported (reporting zones 33-64 and partitions 3-8).
No
Yes
For UL Grade AA / ULC Level 3