03
CONTACT I.D.
04
SIA FSK
05
Pager
06
Residential Dial
07
10 bps, 1400 Hz handshake
08
10 bps, 2300 Hz handshake
Reporting Codes
• SIA - 0 is valid in account or reporting code (not 00 in a
reporting code though)
• ADEMCO Contact ID - 0 is not valid in account or
reporting code (A must be used, 10 in checksum)
• BPS Formats - 0 is not valid in account or reporting
code (A must be used)
• SIA - This format uses 300 Baud FSK as the communi-
cation medium. The account code can be 4 or 6 hexa-
decimal digits in length, all reporting codes must be 2-
digits in length. The SIA format will transmit a 4- (or 6-
digit account code, a 2-digit identifier code and a 2
digit reporting code. The 2-digit identifier is pre-pro-
grammed by the panel.
Telephone Line Monitoring (TLM)
When the TLM Enable option is selected, the panel will
supervise the telephone line and will indicate a Trouble
condition if the telephone line is disconnected.
If the TLM Enable option is ON, the panel will check the
telephone line every 10 seconds. If the telephone line volt-
age is below 3V for the number of checks programmed in
the TLM Trouble Delay section, the panel will report a
TLM Trouble. The default number of checks is 3. Enter a
number from (000) to (255) in the TLM Trouble Delay sec-
tion to change the number of checks before the TLM Trou-
ble is reported. Programming a delay means that a
momentary interruption of the telephone line will not
cause a Trouble condition.
If the TLM Trouble Beeps When Armed option is
enabled, the panel will indicate a TLM Trouble at the key-
[377] - COMMUNICATION VARIABLES
Swinger Shutdown (Alarms & Restores)
This value defines the number of attempts (alarm and restoral pairs) per zone that the communicator will make before it shuts down for that zone ('swinger
shutdown'). Program 001 or 002 in this entry. When programmed as 000, the communicator will shut down after 2 Alarm/Restoral pairs.
Different limits can be programmed for Zone Alarms, Zone Tampers and Maintenance signals. After the panel has communicated the programmed number
of transmissions for an event it will no longer report that event until the swinger shutdown is reset. For example, the swinger shutdown limit for Zone Alarms is
set to [001]. The panel will not send more than 1 alarm signal for each zone with a swinger attribute until the swinger shutdown is reset.
The Bell output will not be activated for alarms on zones that have exceeded the limit of alarms set in the Swinger Shutdown counter. Swinger shutdown on
global zones will log once to the System Area.
NOTE: Swinger Shutdown will reset on all partitions when any partition on the system is armed, or every day at midnight. Once reset, the panel
will again communicate normally
NOTE: The Bell and event buffer can follow Swinger Shutdown if enabled.
Swinger Shutdown (Tampers & Restorals)
This value defines the number of times the same system Tamper type event will occur before stopping transmissions. Valid entries are 000 to 014.
Swinger Shutdown (Maintenance Troubles & Restorals)
This value defines the number of times the same system Maintenance (Trouble) type event will occur before stopping transmissions. Fire Troubles will follow the
Maintenance Swinger Shutdown Variable. Swinger Shutdown is enabled on Zone Types [01]-[06] and [25] on all panels by default, and on all definitions. Valid
entries are 000 to 014.
Communication Delay (Seconds)
This value defines the delay before transmission. The delay is for zones which have the Transmission Delay attribute enabled. Program a time from 015 to 045
seconds. This communications transmission delay will be by partition. Each partition will share the same active timer, so if the delay is already active due to an
alarm on a different partition, then any new activity on yet another partition will not restart the communications delay timer.
NOTE: If global zones are used with communications delay, then to stop all alarms from being sent when the communications delay expires,
access codes must be entered on all partitions that went in alarm from that global zone.
NOTE: If transmission delay starts on one partition, other partitions cannot cancel it. If transmission delay is active on more than one partition,
and a code is entered on one of them, that partition's transmission delay will be cancelled.
NOTE: For UL installations the entry delay plus communication delay cannot exceed 60 seconds.
Refer to Zone Attributes Section [101]-[164], Option [7]
AC Failure Communication Delay (Minutes/Hours)
This value determines the delay before an AC Failure or AC Restoral is reported. The AC failure or restoral is still displayed immediately. Valid entries are from
000 to 255 minutes/hours.
NOTE: Selection of minutes or hours for the delay is set in section [382], Option 6.
NOTE: If AC Failure Communications Delay is programmed as 000, the AC Failure Trouble reporting code will be sent immediately*.
*NOTE: Do not use this section for central & remote fire applications.
pad while the system is armed. To activate the bell output
in the case of a TLM Trouble while the system is armed,
the TLM Audible (Bell) When Armed option must be
selected.
When the Trouble condition is restored, the panel can
send a TLM Restoral reporting code. Any events which
occur while the telephone line is down will also be com-
municated.
If the LINKS1000 Cellular Communicator, or LINKS2X50
is being used, the panel can be programmed to report a
TLM Trouble reporting code.
[351]-[376] - Communicator Call Directions
For events from each Call Direction group the control
panel can call 2 different phone numbers and use the
LINKS as backup or as a redundant communicator for
one or both numbers. The third phone number can only
be used as a backup or alternate to the first.
Each report falls under one of the following 5 Groups:
1. Partition X Alarms & Restorals
2. Partition X Openings & Closings
3. Partition X Tampers & Restores
4. System Maintenance Alarms & Restorals
5. System Test Transmissions
Each group can be assigned to the following Call Direc-
tions
1. Option 1 - 1st Telephone Number (and 3rd Telephone
Number if enabled for alternate or backup)
2. Option 2 - 2nd Telephone Number
3. Option 3 - 1st Telephone Number via LINKS (and 3rd
Telephone Number if enabled for alternate or backup)
4. Option 4 - 2nd Telephone Number via LINKS
5. Option 5 - Alternate Communicator. This allows the
panel to have control of what types of events the
LINKS2X50 products will communicate. This Call Direc-
tion is enabled at default.
36