DSC PC5020 Power864 Installation Manual page 45

Hide thumbs Also See for PC5020 Power864:
Table of Contents

Advertisement

[381] - SECOND COMMUNICATOR OPTION CODES
Option
Communicator Code
8
Local Mode
[382] - THIRD COMMUNICATOR OPTION CODES
Option
Communicator Code
1
Contact I.D. Partial Closing
Identifier
2
Walk Test Communication
3
Communications Cancelled
Message
4
Call Waiting Cancel
5
T-Link
6
AC Failure Transmission
Delay
7-8
[390]-[393] LINKS Preambles
Downloading can be performed through the LINKS1000
cellular communicator if the telephone line is discon-
nected. If using the LINKS1000 with Call Back, you need
to program the LINKS1000 Preamble with the download-
ing telephone number in order for the panel to call the
computer correctly.
LINKS1000 Cellular Communicator
The LINKS1000 cellular communicator can be used three
different ways: as the sole communicator for the panel, as
a backup for either or both telephone numbers, or as a
redundant backup to the land line communicator (the
panel will call both the land line and via the LINKS1000).
A LINKS1000 Preamble is programmable for each tele-
phone number in the event that the land line number is
local but the LINKS1000 is required to dial an exchange.
When programming a LINKS1000 Preamble, all unused
digits must be programmed with a Hex decimal 'F'.
Sole Communicator
The panel can be programmed to report only using the
LINKS1000 cellular communicator when an event occurs.
To program this select only the LINKS1000 for the Com-
municator Call Direction Options for the event. In addi-
tion the Call LINKS1000 as well as Land Line option
must also be enabled. When the selected event occurs the
panel will only attempt to call the central station using
the LINKS1000.
NOTE: If a LINKS1000-only event fails to communicate,
the LINKS1000 must successfully communicate a
LINKS1000-only event in order for the FTC Trouble to
clear.
P r o g r a m m i n g S e c t i o n s : 5 . 6 C o m m u n i c a t o r P r o g r a m m i n g P W S S e c t 6
On/Off
Description
ON
Local Mode Enabled. The panel will always send events to the PC5108L module. Downlook
will not be initiated if requested.
OFF
Local Mode Disabled. The panel will only send events that are being communicated to the
PC5108L module. Downlook will be initiated when requested.
On/Off
Description
ON
Partial Closing Identifier = 5. Contact I.D. uses 5 as the identifier for the Partial Closing event.
OFF
Partial Closing Identifier = 4. Contact I.D. uses 4 as the identifier for the Partial Closing event.
This option is defaulted OFF.
ON
Zone Alarms Communicate during Walk Test Enabled. Zone alarms that occur during Walk
Test will communicate if programmed to do so.
OFF
Zone Alarms Communicate during Walk Test Disabled. Zone alarms that occur during Walk
Test will not communicate even if programmed.This option is defaulted OFF. NOTE: This
option must be OFF for SIA FAR installations.
ON
Communications Cancelled Message Enabled. The 'Communications Cancelled'
(LCD5500Z) or 'CC' (LCD5501Z) message will be displayed if alarms are acknowledged during
the Transmission Delay time. This message will be displayed for 5 seconds on all keypads on the
partition. The acknowledgment can be from an access code, disarm function key, or a keyswitch
zone. Caution: This option must NOT be turned OFF for SIA-FAR installations.
OFF
Communications Cancelled Message Disabled. The 'Communications Cancelled' message
will not be displayed. This option is defaulted OFF.
ON
Call Waiting Cancel Enabled. The Call Waiting dialing string programmed in Section [304] will
be dialed before the first attempt of each phone number. All subsequent dialing attempts to the
same phone number will not use the Call Waiting Cancel dialing string.
OFF
Call Waiting Cancel Disabled. The Call Waiting dialing string will not be dialed. This option is
defaulted OFF. Note: A Call Waiting Cancel on a non-call waiting line will prevent successful
connection to the central station.
ON
The panel will communicate with a T-Link module connected to the PC-Link header.
OFF
The T-Link interface is disabled.
*NOTE: Not investigated by UL.
ON
AC Failure Transmission Delay. Delay is in hours.
NOTE: For central & remote fire applications, this option must be ON.
OFF
AC Failure Transmission Delay. Delay is in minutes.
ON
For Future Use
39
Backup Communicator
The panel can be programmed to call using the
LINKS1000 cellular communicator if the panel is having
difficulty communicating an event using the land line. To
program
this
select
the
LINKS1000 options for the Communicator Call Direction
Options for the event. The LINKS1000 is backup of Land
Lines option must also be selected.
When used as a backup communicator the panel will
attempt to call the central station in the following manner:
• the panel will try to call using land lines - if unsuc-
cessful the panel will try to call using the LINKS1000
• if unsuccessful the panel will try to call using the land
lines
• if unsuccessful the panel will try to call using the
LINKS1000
This process will continue until the panel has successfully
communicated with the central station or the Maximum
Dialing Attempts has been reached.
Redundant Communicator
The panel can be programmed to call using the land line
and the LINKS1000 cellular communicator when an event
occurs. To program this select both the telephone number
and the LINKS1000 options for the Communicator Call
Direction Options for the event. In addition the Call
LINKS1000 as well as Land Line option must be
selected. The panel will call the LINKS1000 and then call
the land line when reporting the selected event.
telephone
number
and