B.6 Sensor Reset for 4-Wire Smoke Detectors
AUX Connection
4-WIRE SMOKE DETECTORS
Smoke Detector must be latching type (such as
DSC MN240 Series).
To reset smoke detectors, enter [ ] [7] [2].
1
PGM 2
+ AUX
IN
-
SMOKE
NO
DETECTOR
IN
ALM
POWER
+
12 VDC
OUT
LATCHING 4-WIRE
WHT
SMOKE DETECTOR
FOR EXAMPLE,
DSC MN240 Series.
EOLR-2
END OF LINE RESISTOR
5600 0.5W
B.7 Other PGM Connections
PGM1 PGM2 PGM3 PGM4
NOTE: For devices requiring more than 50mA, use a relay
(DSC RM-1) or UL-recognized parts only for this application.
NOTE: The RM-1 relay module cannot be installed outside of
the main panel enclosure.
Zone Input
RM-1 POWER LOOP
SUPERVISORY RELAY
BLK
WHT
12V
COM
DC 35mA MAXIMUM
-
OUT
ALARM
INITIATING
+
LOOP
RESISTANCE:
100Ω
RED
GRN
Refer to installation guidelines in
Installation Manual and detector manufacturer's
literature when locating smoke detectors.
PGM1 PGM2 PGM3 PGM4