Making An Electrical Connection; Terminal Box Connections - Logik LBPCKX12 Instruction & Installation Manual

Electric fan assisted oven
Table of Contents

Advertisement

Making an Electrical Connection

An approved suitable cable must be connected from the Consumer Unit (main fuse box)and be protected by its
own 30amp fuse or Micro Circuit Breaker (MCB).
The electrician must provide a fused double-pole isolation switch, which disconnects both the line (live) and
neutral conductors, with a contact separation of at least 3 mm incorporated into the fixed wiring. The fused
switch should be fitted to the kitchen wall, and must be placed in an easy accessible position in accordance
with IEE regulations. Connect the fused switch to a junction box which should be fitted on the wall. The ovens
power supply cable can then be connected. Connect one end to the junction box and connect the other end
to the ovens power connection box which is located at the back of the oven. Remove the cover of the power
connection box and install the cable, in accordance with the connection diagram. The power supply cable must
be positioned away from direct heat sources. It should not be subjected to a temperature rise of more than 50°C
above room temperature.

Terminal Box Connections

For this oven, the cable type must be a minimum of H05VV-F (PVC
insulated and sheathed) 3 cores x 4mm
made as detailed below.
This appliance must be earthed
Green / Yellow (Earth) to the PE ( ) terminal
Brown (Live) wire to the terminal marked L
Blue (Neutral) wire to the the terminal marked N
Ensure the cable exits through the cable grip clamping on the outer
sheath of the cable and fix in place by tightening the fixing screw.
Ensure all screws are adequately tightened. Do not over tighten as you
may risk damaging the screw threads.
* All images are for indication only; please refer to your individual unit for actual item.
16
and the connection should be
2
L
N
PE
Grounding lead must be connected
to screw with
symbol.

Hide quick links:

Advertisement

Table of Contents
loading