The panels of the adjacent cabinets must be made of heat-resistant material.In particular ,
cabinets with a veneer exterior must be assembled with glues which can withstand temperatures
of up to 100℃.
In compliance with current safety standards, contact with the electrical parts of the oven must
not be possible once it has been installed.
All parts, which ensure the safe operation of the appliance, must be removable only with the
aid of a tool.

11. APPLIANCE CONNECTIONS

11.1 Fitting on a Power Supply Cable
Those ovens equipped with a three-pole power supply cable are designed to operate with an
alternating current .The wire for earthling the appliance is yellow-green in color.
Opening the terminal board:
· Using a screwdriver ,prize the bolt on the side tabs of the Terminal board cover;
· Unscrew the bolt, pull open the cover of the terminal board .
To install the cable, proceed as follows:
· Remove the wire clamp screw and the three contact screws L-N -
· Fasten the wires beneath the screw heads using the following color scheme :Blue (N) Brown (L)
Yellow-Green
· Fasten the supply cable in place with the clamp and close the cover of the terminal board.
· The ac power supply should be 220-240 v, 50/60 Hz, the minimum 15 A distribution circuit fuse,
or at least 16 a distribution circuit breaker.
11.2 Connecting the supply cable to the mains
Install a standardized plug corresponding to the load indicated on the data plate. When
connecting the cable directly to the mains, install an Omni polar circuit breaker with a minimum
contact opening of 3 mm between the appliance and the mains .The Omni polar circuit breaker
should be sized according to the load and should comply with current regulations (the earth wire
should not be interrupted by the circuit breaker).
The supply cable should be positioned so that it does not reach a temperature of more than
50℃with respect to the room temperature ,anywhere along its length , or protected by insulation
sleeping having an appropriate rating.
Before making the connection, check that:
· The electrical safety of this appliance can only be guaranteed if the cooker is correctly and
efficiently earthed ,in compliance with regulations on electrical safety. Always ensure that the
earthling is efficient; if you have any doubts call in a qualified technician to check the system .The
manufacturer declines all responsibility for damage resulting from a system which has not been
earthed.
· Before plugging the appliance into the mains ,check that the specifications indicated on the date
plate (on the appliance and /or packaging )correspond to those of the electrical mains system of
your home .
· Check that the electrical capacity of the system and sockets will support the maximum power of
the appliance ,as indicated on the data plate .If you have any doubts, call in a qualified
technician.
· If the socket and appliance plug are not compatible ,have the socket replaced with a suitable
model by a qualified technician . The latter, in particular, will also have to ensure that the cross
sections of the socket cables are suitable for the power absorbed by the appliance. The use of