(5) Fuse list

Fuse list mounted on the respective printed circuit boards in the control box is shown in the table below.
No.
Location
1
SDC p.c.b. F1
2
SDC p.c.b. F2
3
SDC p.c.b. F3
SDC p.c.b. F4
SDC p.c.b F5
FLT p.c.b. F1
FLT p.c.b. F2
FLT p.c.b. F3
(FLT-T p.c.b. only)
Kind
250V/5A time-lag fuse ø5.2 X L20
250V/3.15A time-lag fuse ø5.2 X L20
250V/2A fast-blow type fuse ø5.2 X
L20
250A/4A time-lag fuse ø5.2 X L20
250V/4A time-lag fuse ø5.2 X L20
250V/20A time-lag fuse ø6.35 X L30
250V/20A time-lag fuse ø6.35 X L30
250V/20A time-lag fuse ø6.35 X L30
1
2
3
JUKI Part No.
HF0013050P0
HF00130315S
HF003000200
HF0089040P0
HF0089040P0
HF006802000
HF006802000
HF006802000
1 For stepping motor power supply protection
5A (time-lag fuse)
2 For solenoid and stepping motor power supply
protection
3.15A (time-lag fuse)
3 For control power supply protection
2A (fast-blow type fuse)
92
Remarks
For stepping motor/knife solenoid
power (+48V) protection
Mounted on the fuse clip
1 pc. is packed together as
accessories.
For stepping motor/tension
solenoid power (+33V) protection
Mounted on the fuse clip
1 pc. is packed together as
accessories.
For LCD/fan motor power (+24V)
protection
Mounted on the fuse clip
1 pc. is packed together as
accessories.
For switching power primary
circuit protection
Fixed on p.c.b. by soldering
For switching power primary
circuit protection
Fixed on p.c.b. by soldering
For AC input protection
Fixed on p.c.b. by soldering
For AC input protection
Fixed on p.c.b. by soldering
For AC input protection
Fixed on p.c.b. by soldering