Download Print this page

Kinetico 2020C Installation Instructions Manual page 6

Hide thumbs Also See for 2020C:

Advertisement

2020c water softener
Installation Instructions
2020c compact water softener (Hf)
Salt Setting
1
2
.22kg
0-75ppm
76-149ppm
.3kg
0-92ppm
93-181ppm
Litres between
1479
740
regenerations
Maximum Hardness
30gpg (515ppm)
Media Tank Size
6" x 13" (152mm x 330mm)
Cabinet Dimentions @ base
H 19" x D 18" x W 8" (H 485mm x D 455mm x W 210mm)
Resin per tank
4.4 litres
Tank Freeboard
PACKED
Salt used per cycle
0.22kg or 0.3kg
Regeneration Time
11 Minutes
Service Flow Rate @ 15 psi drop
32 l/m
Service Flow Rate @ 30 psi drop
51 l/m
Backwash Rate
2.7 l/m
Resin Type
Monosphere
Pipe connections - in/out
3/4"
Min./Max. Operating Pressure
15/125 PSI (0.83 BAR/8.3 BAR)
Min./Max. Operating Temperature
35° - 120° F (2° - 49°C)
Minimum Operating Flow
0.18 l/m
Water used per cycle
18.9 litres
19" (485mm)
10
3
4
5
150-220ppm
221-289ppm
290-357ppm
182-268ppm
269-352ppm
353-435ppm
493
370
296
8" (210mm)
18" (455mm)
visit www.kinetico.co.uk
6
358-423ppm
On page 11, there is a diagram of the brine valve that is used in the 2020C water softener.
436-515ppm
There are 2 brine valve settings that can be selected dependant on the incoming water
247
hardness (see disc chart on page 8 and 9).
Figure 7 shows the 0.22kg setting with the yellow float cup pushed completely down the
rod when the valve is de-pressurised.
Figure 8 shows the 0.3kg setting which has the yellow float cup raised by 6mm. The top
of the float cap should be in line with the black mark on the rod when the valve is de-
pressurised..
Refer to your authorised Kinetico dealer for your warranty information. Alternativly, you
can visit our website: www.kinetico.co.uk
freephone 0800 0151 380
(109mm)
(114mm)
2020c water softener
Installation Instructions
11

Hide quick links:

Advertisement

loading