Fireplace Installation; Installation - Dimplex XLF50 Owner's Manual

Hide thumbs Also See for XLF50:
Table of Contents

Advertisement

Fireplace Installation

CAUTION: Ensure installation
does not allow fireplace to be in
direct contact with building vapor
barrier or insulation and meets all
local building code.
!
NOTE: A dedicated, properly
fused 15 Amp circuit is re-
quired, rated for the appropri-
ate voltage (120V, 240V).
WARNING: Construction and
wiring must comply with local
building codes and other ap-
plicable regulations to reduce
the risk of fire, electric shock
and injury to persons.
WARNING: To reduce the risk
of fire, electric shock or injury to
persons, always use a licensed
electrician.
WARNING: To reduce the risk
of fire, do not store or use gaso-
line or other flammable vapors or
liquids in the vicinity of the heater.
1. Select a location that is not
susceptible to moisture and
is away from drapes, furniture
and high traffic.
2. Unpack the fireplace and hard-
ware from the box.
!
NOTE: Leave the front glass
and partially reflective glass,
safely, in the box until the time
you are ready to install it.
3. Store the fireplace in a safe,
dry and dust free location until
you are ready to install the
fireplace.

Installation

CAUTION: Two people will be
required for various steps of
this procedure.
This design of this unit allows
three options for installation:
partial recess, flush mounted or
sub-surface mounted.
CAUTION: Sub-surface
mounting should be limited
to ½ in. (10 mm) to ensure
adequate air flow of heated air
out of the firebox area.
1. Prepare a wall with a framed
opening of 16 in. (40.6 cm)
high,
• XLF50 - 50 ⅝ in. (128.7 cm)
• XLF74 - 74 ⅝ in. (189.7 cm)
• XLF100 - 100 ⅝ in. (255.7 cm)
wide, with a bottom sill that is
a minimum of 4 in. (10.2 cm)
deep. The sill can be con-
structed to support the front
of the unit to allow the power
supply wires to easily be run
behind or flush with the back
of the unit and a pass thru
7

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Xlf100Xlf74

Table of Contents