Page 1
Service Manual Models XHD23L/XHD23G XHD26L/XHD26G XHD28L/XHD28G XHD33L/XHD33G DF26L-PRO DF26DWC-PRO DF28L-PRO DF28DWC-PRO Part Number 6909940XXX 6913820XXX 6909850XXX 6913830XXX 6909970XXX 6913840XXX 6913820XXX 6913830XXX 6913840XXX 6910090XXX IMPORTANT SAFETY INFORMATION: Always read this manual first before attempting to service this firebox. For your safety, always comply with all warnings and safety instructions contained in this manual to prevent personal injury or property damage.
NOTE: Procedures and techniques that are considered important enough to emphasize. CAUTION: Procedures and techniques which, if not carefully followed, will result in damage to the equipment. WARNING: Procedures and techniques which, if not carefully followed, will expose the user to the risk of fire, serious injury, or death. www.dimplex.com...
Wiring Diagram XHD23 MOD 0-A XHD26 MOD 0-B XHD28 MOD 0-A ALL DF-PRO On log models only Logset or Media Bed LEDs XHD23 MOD B CUTOUT XHD26 MOD C XHD28 MOD B 120V / 12V POWER SUPPLY BLOWER AC / DC...
Accessing Top Components Tools Required: Phillips head screwdriver WARNING: If the firebox was operating prior to servicing, allow at least 10 minutes for the heating elements to cool off to avoid accidental burning of skin. Figure 1 WARNING: Disconnect power before attempting any maintenance to reduce the risk of electric shock or injury to persons.
WARNING: Ensure wires do not come in contact with moving parts by securing wires in cable ties or electrical tape. 5. Reassemble the firebox. www.dimplex.com...
Power Supply Replacement 5. Reconnect the wires. See wiring diagram if needed. WARNING: Ensure wires do not come in contact Tools Required: Phillips head screwdriver with moving parts by securing wires in cable ties or Pliers electrical tape. WARNING: If the firebox was operating prior to 6.
11. Insert stem from flicker rod into the rubber grommet. 12. Reattach the flicker rod retaining bracket. Remove this bracket when 13. Reassemble the firebox. changing icker rod Remove this bracket when changing icker motor Media bed/Log Flame screen retaining set screws bracket screws www.dimplex.com...
Flame LED Strip Replacement Flame Base LED Strip Replacement Tools Required: Phillips head screwdriver Tools Required: Phillips head screwdriver Flathead Screwdriver WARNING: If the firebox was operating prior to servicing, allow at least 10 minutes for the heating WARNING: If the firebox was operating prior to elements to cool off to avoid accidental burning of skin.
1. Follow the instructions for accessing the bottom com- ponents on pages 8-9. NOTE: For XHD23/XHD28 MOD B+, XHD26 MOD C+, and XHD33 skip steps 4-6, as the end of the thermistor 2. Disconnect the cable from the log set by depressing is located at the top, near the power cord.
Troubleshooting Guide PROBLEM CAUSE SOLUTION General Additional appliances may exceed the current rating of the circuit breaker Improper circuit current rating or fuse. Plug unit into another outlet Circuit breaker trips or fuse blows or install unit on a dedicated 15 amp when unit is turned on circuit.
Need help?
Do you have a question about the XHD23 and is the answer not in the manual?