U Series
Fan Forced
Ceiling Mounted Heater
Installation, Operation & Maintenance Instructions
Specifications
MODEL CATALOG
NO.
NO.
VOLTS AMPS
U1000FA QCH1101
120
U1500FA QCH1151
120
240
U2004FA QCH1202
208
277
U2007FA QCH1207
240
WHEN USING ELECTRIC APPLIANCES, BASIC PRECAU-
TIONS SHOULD ALWAYS BE FOLLOWED TO REDUCE THE
RISK OF FIRE, ELECTRIC SHOCK, AND INJURY TO PER-
SONS, INCLUDING THE FOLLOWING:
1. Read all instructions before installing or using this heater.
2. This heater is hot when in use. To avoid burns, do not let
bare skin touch hot surfaces. Keep combustible materials,
such as furniture, pillows, bedding, papers, clothes, etc. and
curtains at least 3 feet (0.9 m) from the front of the heater.
3. Extreme caution is necessary when any heater is used by or
near children or invalids and whenever the heater is left
operating and unattended.
4. Do not operate any heater after it malfunctions. Disconnect
power at service panel and have heater inspected by a rep-
utable electrician before using.
5. Do not use outdoors.
6. To disconnect heater, turn controls to off, and turn off power
to heater circuit at main disconnect panel.
7. Do not insert or allow foreign objects to enter any ventilation
or exhaust opening as this may cause an electric shock, fire,
or damage to the heater.
8. To prevent a possible fire, do not block air intake or exhaust
in any manner.
PPD 41511
WATTS
BTU/HR
8.4
1000
3413
4.2
500
1706
12.5
1500
5120
6.25
750
2560
8.4
2000
6826
4.2
1000
3413
7.3
1500
5120
3.62
750
2560
7.2
2000
6826
3.6
1000
3413
6.3
1500
5120
3.1
750
2560
IMPORTANT INSTRUCTIONS
WARNING
SAVE THESE INSTRUCTIONS
Conforms to ANSI/UL2021
and CSA C22.2 No. 46.
WIRE
SIZE
14AWG
12AWG
14AWG
14AWG
14AWG
14AWG
!
9. A heater has hot and arcing or sparking parts inside. Do not
use it in areas where gasoline, paint, or flammable liquids
are used or stored.
10. Use this heater only as described in this manual. Any other
use not recommended by the manufacturer may cause fire,
electric shock, or injury to persons.
11. This heater is provided with a red alarm light that will illumi-
nate only if the heater has turned off as a result of over-
heating. If you see the light on, immediately turn the heater
off and inspect for any objects on or adjacent to the heater
that may have blocked the airflow or otherwise caused high
temperatures to have occurred. DO NOT OPERATE THE
HEATER WITH THE ALARM LIGHT ILLUMINATING.
12. This heater is intended for comfort heating applications and
not intended for use in special environments. Do not use in
damp or wet locations such as marine or greenhouse or in
areas where corrosive or chemical agents are present.
13. When installing, see INSTALLATION INSTRUCTIONS for
additional warnings and precautions.
14. For safe and efficient operation, and to extend the life of your
heater, keep your heater clean - See MAINTENANCE
INSTRUCTIONS.
12/14
5200-11226-000