Download Print this page

Marley U1000 Insallation & Maintenance Manual

U series fan forced ceiling mounted heaters

Advertisement

Quick Links

U Series
FILE#E21609
Fan Forced Ceiling
Mounted Heaters
Installation & Maintenance Instructions
Dear Owner,
Congratulations! Thank you for purchasing this new heater manufactured by Marley Engineered Prod-
ucts. You have made a wise investment selecting the highest quality product in the heating industry. Please
carefully read the installation and maintenance directions shown in this manual. You should enjoy years
of efficient heating comfort with this product from Marley Engineered Products... the industry's leader in
design, manufacturing, quality and service.
Read Carefully -
These instructions are written to help
you prevent difficulties that might arise during installation of
heaters. Studying the instructions first may save you con-
siderable time and money later. Observe the following pro-
cedures, and cut your installation time to a minimum.
1. To prevent electrical shock, disconnect all power coming to
heater at main service panel before wiring or servicing.
2. All wiring must be in accordance with the National and Local
Electrical Codes and the heater must be grounded as a pre-
caution against possible electric shock.
3. Verify the power supply voltage coming to heater matches the
ratings printed on the heater nameplate before energizing.
4. Do not operate heater without grille installed.
5. Do not insert or allow foreign objects to enter any ventilation or
exhaust opening as this may cause an electric shock, fire,or
damage to the heater.
Nameplate
Model No.
U1000
U1500
U2004
U2007
... The Employees of
Marley Engineered Products
WARNING
!
6. To prevent a possible fire, do not block air intakes or exhaust
in any manner. Keep combustible materials, such as crates,
drapes, etc., away from heater.
7. A heater has hot and arcing or sparking parts inside. Do not
use it in areas where gasoline, paint, or flammable liquids are
stored.
8. This heater is intended for ceiling installation only, at least 6
feet off the floor. Do not install in walls, floor, or other loca-
tions. Do not install closer than 12" to adjacent walls.
9. Use this heater only as described in this manual. Any other
use not recommended by the manufacturer may cause fire,
electric shock, or injury to persons.
10. This heater is not approved for use in hazardous locations as
described by the National Fire Protection Association (NFPA)
nor in corrosive atmospheres such as marine, green house, or
chemical storage areas.
SAVE THESE INSTRUCTIONS
1
Catalog No.
Watts
QCH1101
1000
QCH1151
1500
QCH1202
2000
QCH1207
2000
Volts
120
120
240
277

Advertisement

loading
Need help?

Need help?

Do you have a question about the U1000 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Marley U1000

  • Page 1 You have made a wise investment selecting the highest quality product in the heating industry. Please carefully read the installation and maintenance directions shown in this manual. You should enjoy years of efficient heating comfort with this product from Marley Engineered Products... the industry’s leader in design, manufacturing, quality and service.
  • Page 2 IMPORTANT 6. Connect the supply cable ground wire to green ground screw pro- vided. NOTE: Lead holes for a #8 sheet metal screw have been provided in the WARNING sides of the back box. After the finished wall or ceiling has been put up, drive a # 8(m4) sheet metal screw (recommended 1”) through the side of TO PREVENT HAZARD OF FIRE OR ELECTRICAL SHOCK, DO the box not mounted to the joist.
  • Page 3 INSTALLATION AND WIRING OF HEATER / FAN ASSEMBLY 3. Position the front cover so the four (4) holes on the side align with the tabs on the plastic pieces mounted on the heat deck. 1. Following wiring diagram (Figure 3) connect supply wiring and thermo- 4.
  • Page 4: Important Information

    Marley authorized service center or the Marley Engineered Products Service Center, and we will repair or replace, at our option, at no charge to you with return freight paid by Marley. It is agreed that such repair or replacement is the exclusive remedy available from Marley Engineered Prod- ucts.

This manual is also suitable for:

U1500U2007U2004