Mitsubishi PLA-A12BA Technical Data Book page 40

Split-type, heat pump air conditioners
Table of Contents

Advertisement

PUZ-HA30NHA2
[LEGEND]
SYMBOL
NAME
TB1
Terminal Block<Power Supply, Indoor/Outdoor >
MC
Motor for Compressor
MF1, MF2
Fan Motor
21S4
Solenoid Valve (Four-Way Valve)
63H
High Pressure Switch
63L
Low Pressure Switch
SV
Solenoid Valve (Bypass Valve)
TH3,TH32,TH33
Thermistor<Outdoor Pipe>
TH4
Thermistor<Discharge>
TH6
Thermistor<Outdoor 2-Phase Pipe>
TH7
Thermistor<Outdoor>
TH8
Thermistor<Heatsink>
LEV-A, LEV-B,LEV-C
Electronic Expansion Valve
DCL
Reactor
ACTM
Active Filter Module
CB
Main Smoothing Capacitor
CY1, CY2
Capacitor
C. B.
7
CNF1
1
MF1
(WHT)
MS
3~
7
CNF2
MF2
1
(WHT)
MS
3~
3
2
CNDC
1
(PNK)
CNS
(WHT)
3
TH8
t °
CB
M-NET ADAPTER
SYMBOL
NAME
TB7
Terminal Block<M-net connection>
CN5
Connector<Transmission>
CND
Connector<Power Supply>
CN2M
Connector<M-NET communication>
SW1
Switch<Status of communication>
SW11
Switch<Address setting : 1s digit>
SW12
Switch<Address setting : 10s digit>
LED1
LED<Power Supply : DC5V>
LED2
LED<Connection to Outdoor Unit>
LED3
LED<Transmission : Sending>
LED4
LED<Transmission : Recelving>
LED5
LED<Power Supply : DC12V>
40
PUZ-HA36NHA2
SYMBOL
P.B.
TABU/V/W
TABS/T
TABP1/P2/P
TABN1/N2/N
DS2, DS3
IPM
N.F.
LI / LO
NI / NO
EI, E2
52C
C.B.
SW1
SW4
SW5
63H
63L
TH33
TH32
TH7 TH6 TH3 TH4
t °
t °
t °
t °
t °
t °
2
1
3
1
1
4
1
2
2 1
TH33
TH32
TH7/6
TH3
TH4
(YLW )
(BLK )
(RED)
(WHT )
(WHT )
1
3
63L
1
3
(RED)
63H
(YLW)
CN2
(WHT)
TRANS
1
7
7
F2
F3
CNAC
(WHT)
1
2
F1
F4
3
4
1
P. B.
4
1
CNAF
CNDC
(WHT)
(PNK)
6
2
7
1
1
CN2
3
IPM
(WHT)
7
1
CN3
2
(WHT)
2
CN5
1
2
(RED)
2
1
CN4
2
(WHT)
WHT
TABN
TABP
RED
V
U
W
MS
3~
MC
DCL
RED
BLK
ACTM
w1MODEL SELECT
MODEL
SW6
ON
30N
OFF
1 2 3 4 5 6 7 8
ON
36N
OFF
1 2 3 4 5 6 7 8
w 2. SW5 -1 to 5 : Function Switch
NAME
Power Circuit Board
Connection Terminal<U/V/W-Phase>
Connection Terminal <L/N-Phase>
Connection Terminal<DC Voltage>
Connection Terminal<DC Voltage>
Diode Bridge
Power Module
Noise Filter Circuit Board
Connection Terminal<L-Phase>
Connection Terminal<N-Phase>
Connection Terminal<Ground>
52C Relay
Controller Circuit Board
Switch<Forced Defrost, Defect History Record
Reset, Refrigerant Address>
Switch<Test Operation>
Switch<Function Switch>
LEV-C
LEV-A
LEV-B
M
M
M
3
5
5
1
6
1
6
1
3
1
5
LEV-A
LEV-B
CNVMNT
CNMNT
(WHT)
(RED)
(WHT)
(WHT)
1
14
CNM
(WHT)
5
CN52C
CN4
(RED)
(WHT)
1
2
2 1
1
6
2
LEV-C
2
(BLU)
3
1
3
1
3
1
21S4
SV2
(GRN)
(BLU)
21S4
SV
TABT
BLU
DS3
TABS
WHT
DS2
RED
TABP1
U
4
L1
L2
1
6
RED
P
N1
N2
WHT
Io
w
SW5-6
2
ON
OFF
1 2 3 4 5 6
ON
OFF
1 2 3 4 5 6
SYMBOL
SW6
Switch<Model Select>
SW7
Switch<Function Setup>
SW8
Switch<Function Setup>
SW9
Switch
SWP
Switch<Pump Down>
CN31
Connector<Emergency Operation>
SS
Connector<Connection for Option>
CNM
Connector<A-Control Service Inspection Kit>
CNMNT
Connector
<Connected to Optional M-NET Adapter Board>
CNVMNT
Connector
<Connected to Optional M-NET Adapter Board>
Connector < Connected for Option (Contact Input)>
CNDM
Connector < Connected for Option (Signal output)>
CN51
LED1,LED2
LED<Operation Inspection Indicators>
F1~F4
Fuse < T6.3AL250V >
X51,X52,X55 Relay
When M-NET adapter is connected
5
CN5
SW1
(WHT)
5
1
LED2
LED3
w 1
w 1
LED4
M-NET ADAPTER
2
CN2M
(WHT)
1
CN31
3
1
3
A B S
TB7
1
M-NET
5
SS
(WHT)
BLU
WHT
N. F.
LO
NO
1
2
CN52C
(BLK)
3
1
CNAC2
(RED)
E2
1
3
2
CN5
(RED)
1
CNAC1
(WHT)
EI
U
LI
NI
U
CY1
CY2
L1
L2
GR
S1
S2
S3
TB1
INDOOR
UNIT
POWER SUPPLY
208/230V 60Hz
w Use copper supply wires.
NAME
SW11
SW12
CND
(WHT)
3
1
2
BLK
2
BLK