Mitsubishi PLA-A12BA Technical Data Book page 38

Split-type, heat pump air conditioners
Table of Contents

Advertisement

PUZ-A30/36NHA3
[LEGEND]
SYMBOL
TB1
Terminal Block<Power Supply, Indoor/Outdoor >
MC
Motor for Compressor
MF1
Fan Motor
21S4
Solenoid Valve (Four-Way Valve)
SV
Solenoid Valve (Bypass Valve)
63H
High Pressure Switch
TH3
Thermistor<Outdoor Pipe>
TH6
Thermistor<Outdoor 2-Phase Pipe>
TH7
Thermistor<Outdoor>
TH8
Thermistor<Heatsink>
TH32
Thermistor<Shell>
LEV-A
Electronic Expansion Valve
DCL
Reactor
CY1, CY2
Capacitor
ACTM
Active Filter Module
w
1 MODEL SELECT
MODEL
ON
PUZ-A30N
OFF
ON
PUZ-A36N
OFF
ON
PUY-A30N
OFF
ON
PUY-A36N
OFF
w
2. SW5-1 to 4 : Function switch
M-NET ADAPTER
SYMBOL
TB7
CN5
CND
CN2M
SW1
SW11
SW12
LED1
LED2
LED3
LED4
LED5
38
PUZ-A30/36NHA3-BS
NAME
SYMBOL
P.B.
TABU/V/W
TABS/T
TABP1/P2
TABN1/N2
DS2, DS3
IPM
N.F.
LI/LO
NI/NO
EI, E2
52C
C.B.
F1~F4
SW1
TH32
TH7TH6 TH3
C. B.
CNF1
1
MF1
(WHT)
7
1
2
1
MS
TH32
TH7/6
3~
(BLK)
(RED)
3
2
TRANS
1
CNDC
(PNK)
F2
CNAC
CNS
(WHT)
1
2
(WHT)
F1
3
4
3
1
P. B.
4
1
CNAF
(WHT)
6
7
1
IPM
CN2
(WHT)
7
TH8
1
CN3
2
(WHT)
2
1
CN5
2
(RED)
2
1
CN4
2
(WHT)
TABN
TABP
V
U
MS
3~
w 2
SW6
SW5-5.6
ON
OFF
RED
1 2 3 4 5 6
7 8
1 2 3 4 5 6
ON
BLK
OFF
1 2 3 4 5 6
7 8
1 2 3 4 5 6
ON
OFF
1 2 3 4 5 6
7 8
1 2 3 4 5 6
ON
OFF
1 2 3 4 5 6
7 8
1 2 3 4 5 6
NAME
Terminal Block<M-net connection>
Connector<Transmission>
Connector<Power Supply>
Connector<M-NET communication>
Switch<Status of communication>
Switch<Address setting : 1s digit>
Switch<Address setting : 10s digit>
LED<Power Supply : DC5V>
LED<Connection to Outdoor Unit>
LED<Transmission : Sending>
LED<Transmission : Recelving>
LED<Power Supply : DC12V>
PUY-A30/36NHA3
NAME
Power Circuit Board
Connection Terminal<U/V/W-Phase>
Connection Terminal<L1/L2-Phase>
Connection Terminal<DC Voltage>
Connection Terminal<DC Voltage>
Diode Bridge
Power Module
Noise Filter Circuit Board
Connection Lead<L1-Phase>
Connection Lead<L2-Phase>
Connection Terminal<Ground>
52C Relay
Controller Circuit Board
Fuse<T6.3AL250V>
Switch<Forced Defrost, Defect History Record
Reset, Refrigerant Address>
LEV-A
63H
M
3
1
6
4
1
2
1
3
1
LEV-A
CNVMNT
CNMNT
TH3
(WHT)
(WHT)
(WHT)
(WHT)
1
CNM
1
3
(WHT)
63H
(YLW)
CN52C
CN4
CN2
(RED)
(WHT)
(WHT)
1
2
1
7
1 2
2
2
7
F3
3
1
3
1
3
1
21S4
SV2
F4
(GRN)
(BLU)
21S4
SV
PUZ only
TABT
BLU
DS3
CNDC
(PNK)
2
TABS
WHT
1
DS2
3
TABP1
RED
U
W
MC
4
DCL
L1
L2
1
6
RED
P
L1
N1
N2
WHT
Io
ACTM
POWER SUPPLY
208 / 230V 60Hz
wUse copper supply wires.
PUY-A30/36NHA3-BS
SYMBOL
NAME
SW4
Switch<Test Operation>
SW5
Switch<Function Switch>
SW6
Switch<Model Select>
SW7
Switch<Function Setup>
SW8
Switch<Function Setup>
SW9
Switch
SWP
Switch<Pump Down>
CN31
Connector<Emergency Operation>
LED1,LED2
LED<Operation Inspection Indicators>
SS
Connector<Connection for Option>
CNM
Connector<A-Control Service Inspection Kit>
CNMNT
Connector<Connected to Optional M-NET Adapter Board>
CNVMNT
Connector<Connected to Optional M-NET Adapter Board>
CNDM
Connector< Connected for Option (Contact Input)>
CN51
Connector< Connected for Option (Signal output)>
X51,X52,X55 Relay
When M-NET adapter is connected
5
SW1
5
1
5
LED2
LED3
w1
w1
LED4
5
M-NET ADAPTER
2
1
(WHT)
14
CN31
3
A B S
TB7
M-NET
SS
(WHT)
N. F.
LO
NO
1
2
3
1
E2
2
1
3
2
1
EI
U
LI
NI
U
CY1
CY2
L2 GR
S1 S2 S3
TB1
INDOOR
UNIT
SW11
SW12
CND
3 1
2