Temporary Operation; Air Purifying Control - Toshiba RAS-B10GKVP-E Service Manual

Hide thumbs Also See for RAS-B10GKVP-E:
Table of Contents

Advertisement

Item
Operation flow and applicable data, etc.
11. Temporary
Pressing [RESET] button starts the temporary
operation
operation of [AUTO] operation. When keeping [RE-
SET] button pressed for 10 seconds or more, the
temporary [COOL] operation is performed.
Filter lamp ON
NO
Did you press [RESET] button
for 3 seconds or more?
YES
Did you press [RESET] button
for 10 seconds or more?
NO
Switch to [AUTO RESTART] control.
12. Air purifying
This function generates nagative ion while cleaning the air in the room.
control
If air purifier-ON signal is received while the air conditioner stops, the air purifier starts operation,
and if it is received while the air conditioner operates, the air conditioner and the air purifier start
operation.
The air ion generator operates linked with the air purifying operation.
Present status
Stop
Air purifier only
Air conditioner
Joint use of AC and air purifier
Air purifying operation
AC + Air purifying operation
Sending air purifier-ON
1
1
Air conditioner stops
Operation lamp ON
*1
Memory position
of louver/COOL
*2
Fan ON
Air purifier ON
Air purifying operation
Tel: 01823 665660
Heronhill - for all your Toshiba requirements
YES
Press RESET button.
NO
Temporary [AUTO] operation
YES
Temporary [COOL] Operation
Operation button
PURE button
Air conditioner
Air purifier
AC operation*
Stop (All)
AC + Air purifier
AC + Air purifier
AC operation
Louver*1
Fan speed *2
Cooling position
AUTO, L, L+, M, M+, H
Follows to AC operation
Follows to AC operation
2
,
2
Air conditioner operates
Start of air purifier-ON
Air conditioner +
air purifier operate
www.heronhill.co.uk
1) When pressing [RESET] button, the
temporary [AUTO] operation starts.
2) When keeping [RESET] button pressed
for 3 seconds or more, Pi, Pi, Pi sound is
heard and [AUTO RESTART] control is
changed.
3) When keeping [RESET] button pressed
for 10 seconds or more, "Pi" sound is
heard and the temporary [COOL]
operation starts.
4) If the filter lamp goes on, press [RESET]
button to go off the filter lamp, and then
press [RESET] button again.
5) To stop the temporary operation, press
the button again.
* When the previous operation was the
operation of air conditioner + air purifier,
an operation of air conditioner + air purifier
starts by pushing AC button on the remote
controller.
(Operation of air conditioner + air purifier
All stop
is stored in memory.)
All stop
*1 Swing is available
*2 Fan speed is Fan Auto mode varies in
order, (M + 1) → (L) → (L–) → (SL).
Sending air purifier-OFF
3
Air purifier operates
Operation lamp OFF
Fan stop
Air purifier-OFF
Louver close
All stop
– 47 –
Description
3
,
4
4
Air conditioner +
Air purifier operate
Filter-OFF
Air conditioner operates
Fax: 01823 665807

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents