Outdoor Fan Motor Control - Toshiba RAS-B10GKVP-E Service Manual

Hide thumbs Also See for RAS-B10GKVP-E:
Table of Contents

Advertisement

Item
3. Outdoor fan
The blowing air volume at the outdoor unit side is controlled.
motor control
Receiving the operation command from the controller of
indoor unit, the controller of outdoor unit controls fan speed.
* For the fan motor, a DC motor with non-stage variable
speed system is used.
However, it is limited to 8 stages for reasons of controlling.
Air conditioner ON
(Remote controller)
Indoor unit controller
1) Outdoor unit
operation command
(Outdoor fan control)
2) Fan speed ≥ 400
when the motor stopped.
NO
Fan motor ON
3) Fan lock
NO
4) Motor operates as shown in the table below.
Cooling operation, dry operation
RAS-M18GAV-E, RAS-M18GACV-E
Compressor revolution (rps)
Normal
operation
Econo
operation
To is abnormal
RAS-M14GAV-E, RAS-M14GACV-E
Compressor revolution (rps)
Normal
operation
Econo
operation
To is abnormal
Tel: 01823 665660
Heronhill - for all your Toshiba requirements
Operation flow and applicable data, etc.
YES
OFF status of
fan motor continues.
YES
Air conditioner
OFF
~20
To > 38°C
450
28 < To < 38
450
15 < To < 28
350
10 < To < 15
350
5.5 < To < 10
300
0 < To < 5.5
300
To > 38°C
450
To < 38°C
450
450
To: Outdoor sensor temp. (°C) (rpm)
~20
To > 38°C
450
28 < To < 38
450
15 < To < 28
350
10 < To < 15
350
5.5 < To < 10
300
0 < To < 5.5
300
To > 38°C
450
To < 38°C
450
450
To: Outdoor sensor temp. (°C) (rpm)
– 40 –
www.heronhill.co.uk
1) The operation command sent
from the remote controller is
processed by the indoor unit
controller and transferred to the
controller of the outdoor unit.
2) When strong wind blows at
outdoor side, the operation of air
conditioner continues with the
fan motor stopped.
3) Whether the fan is locked or not
is detected, and the operation of
air conditioner stops and an
alarm is displayed if the fan is
locked.
4) According to each operation
mode, by the conditions of
outdoor temperature (To) and
compressor revolution, the speed
of the outdoor fan shown in the
table is selected.
Alarm
display
~30
~46
46~
700
750
850
650
700
750
550
650
700
550
550
550
450
450
550
350
350
450
650
700
750
550
650
700
650
700
750
~30
~60
60~
700
750
850
650
700
750
550
650
700
550
550
650
450
450
550
350
350
450
650
700
750
550
650
700
650
700
750
Description