No.
Part name
Cross flow fan
<Caution at reassembling>
8
1) At assembling work of the bearing base,
2) To incorporate the fan motor, remove the fan
Tel: 01823 665660
Heronhill - for all your Toshiba requirements
Procedures
check that the drain pipe is surely incorpo-
rated in the back body.
(Otherwise, water leak is caused.)
motor rubber (at shaft core side), incorporate
the motor into the position in the following
figure, and then install the fan motor.
Drain pipe
• Install the cross flow fan so that the right
end of the 1st joint from the right of the
cross flow fan is set keeping 70.5 mm from
wall of rear plate of the main unit.
• Holding the set screw, install the cross flow
fan so that U-groove of the fan motor comes
to the mounting hole of the set screw.
• Perform positioning of the fan motor as
follows:
• When assembling the fan motor, the fan
motor must be installed in such a way that
the fan motor leads will be taken out is
positioned at the bottom front.
• After assembling the two hooking claws of
the motor band (right) into the main body,
position the fan motor, insert it, and then
secure the motor band (right) using the two
fixing screws.
U groove
– 105 –
www.heronhill.co.uk
Remarks
Bearing base
Joint
70.5mm
Fax: 01823 665807