Electronic Ignition; Standing Pilot Ignition - Heatilator GCBC36LE Installation Instructions Manual

Caliber series b-vent series decorative gas appliance
Table of Contents

Advertisement

STEP 8 - Wiring
A. ELECTRONIC IGNITION
1. Appliance Requirements. This appliance requires a
110VAC supply from a wall switch to the appliance junction
box for operation. A wiring diagram is shown in Figure 12.
2. Optional Accessories Requirements. Wiring for optional
accessories should be done now to avoid reconstruction.
B. STANDING PILOT IGNITION
1. Appliance requirements. A wiring diagram is shown in
Figure 13.
2. Optional Accessories Requirements. Wiring for optional
accessories should be done now to avoid reconstruction.
12-97
Figure 12
Electronic Ignition Wiring Diagram
Figure 13
Standing Pilot Wiring Diagram
11i
Note: This appliance must be electrically
wired and grounded in accordance with local
codes or, in the absence of local codes, with
National Electric Code ANSI/NFPA 70-latest
edition or the Canadian Electric Code, CSA
C22.1.
Detailed Picture of Junction Box
Wa r n i n g
: This appliance DOES NOT require
a 110VAC supply for operation. Connecting
the appliance/wall switch to a 110V AC supply
will cause the unit to malfunction and destroy
the valve and thermopile.
Detailed Picture of Junction Box