14. Health and safety of the user

Noise information
Powder-actuated tool
Type:
Modell:
Caliber:
Power setting:
Application:
Declared measured values of noise characteristics according to 2006/42/EC Machinery Directive in
conjunction with E DIN EN 15895
Noise (power) level:
Emission noise-pressure level in the work station:
Peak sound pressure emission level:
Operation and set-up conditions:
Set-up and operation of the pin driver in accordance with E DIN EN 15895-1 in the semi-anechoic test room of
Mü l ler-BBM GmbH. The ambient conditions in the test room conform to DIN EN ISO 3745.
Testing procedure:
Enveloping surface method in anechoic room on reflective surface area in accordance with E DIN EN 15895, DIN
EN ISO 3745 and DIN EN ISO 11201.
NOTE: The noise emissions measured and the associated measurement uncertainty represent the upper limit for
the noise values to be expected during the measurements.
Variations in operating conditions may cause deviations from these emission values.
1
± 2 dB (A) /
2
± 2 dB (A) /
Vibration
The declared total vibration value according to 2006/42/EC does not exceed 2.5 m/s
Further information regarding the health and safety of the user can be found at the Hilti web site:
www.hilti.com/hse
Printed: 08.07.2013 | Doc-Nr: PUB / 5129667 / 000 / 01
DX 460
Serial production
6.8/11 black
2
Fastening 24 mm thick wood to concrete (C40) with X-U 47P8
3
± 2 dB (C)
L
1
105 dB(A)
WA, 1s
L
2
101 dB(A)
pA, 1s
L
3
133 dB(C)
pC, peak
2
.
en
13