5. Technical data

en
Tool DX 460 SM
Weight:
Tool length
Nail length
Cartridges
Magazine capacity
Power regulation

6. Before use

6.1 Tool inspection
● Ensure that there is no cartridge strip in the tool. If
there is a cartridge strip in the tool, remove it by hand
from the tool.
● Check all external parts of the tool for damage at reg-
ular intervals and check that all controls operate prop-
erly. Do not operate the tool when parts are damaged or
when the controls do not operate properly. If necessary,
have the tool repaired at a Hilti service centre.
● Check the buffer and piston for wear (see 8. Care and
maintenance).
aa
6.2
Fitting the MX SM magazine to an existing DX460
tool.
1. Ensure that there is no cartridge strip in the tool. If
there is a cartridge strip in the tool, remove it by hand
from the tool.
2. When fitting the magazine to an existing DX 460 tool
press the unlock key.
3. Unscrew the fastener guide of the single tool.
4. Remove the fastener guide with buffer and the pis-
ton. Store these parts separately – they must not be
used together with the MX SM fastener magazine.
5. Use only the X-460-PSM piston. The designation is
marked on the piston in the position shown in the pic-
ture.
6. Insert the X-460-PSM piston into the tool and push
it backwards as far as it will go.
7. Push a reinforced stop buffer X-460-B onto the MXSM
fastener magazine.
6
Printed: 08.07.2013 | Doc-Nr: PUB / 5129667 / 000 / 01
DX 460
3.96 kg (8.50 lb)
max. 22 mm
6.8/11 M (.27 cal short) red, purple
4 power levels
Magazine MX 72
Weight
Nail length
472 mm
Magazine capacity
Nails
10 nails
Right of technical changes reserved
Note: Always use the tool with the buffer in place to
avoid damage to the tool.
8. Firmly press the XM SM fastener magazine on the gas
return unit of the tool.
9. Fully screw the magazine on the tool until it clicks into
place.
Note: The MX SM fastener magazine must only be used
with a DX 460 tool.
aa
6.3
Fitting the DX 460 SM
to the standup handle X-SH 460
1. Ensure that there is no cartridge strip in the tool. If
there is a cartridge strip in the tool, remove it by hand
from the tool.
2. Unscrew the knurled screw on the tool casing of the
standup handle X-SH 460
3. Open the metal clamping bar.
4. Insert the DX 460 tool into the handle casing.
5. Secure the DX 460 tool with the clamping bar
6. Tightening the clamping bar with the knurled screw
Note: The firing lever must be positioned in front of
the trigger.
7. When fastening, position the handle with the tool at
right angles to the working surface, press down the
handle X-SH 460 and then pull the trigger.
8. Warning: Never operate the handle with the DX 460
tool up side down!
Note: The disassembly of the standup handle works in
the reverse order, starting with pulling the cartridge strip
out of the tool.
0.98 kg (2.15 lb)
max. 22 mm
10 nails
X-EDNK 22 THQ 12M (HSN 22)
X-EDN 19 THQ 12M (HSN 19)
X-ZF 22 THS 12M (FDN 22)