Tab.17 List of parameters accessible to the user
Parameters
AP073
AP074
CP010
CP040
CP071
CP072
CP320
CP350
CP360
CP540
CP570
8.2
Setting the parameters
7642066 - v01 - 29092015
8.1.5 PCB parameters for the PCB + sensor kit for circuits with
mixing valve
Certain parameters are displayed:
Description
SUMMER / WINTER set point switch:
Can be set from 15 to 30°C
Set to 30.5°C = function deactivated
SUMMER override:
0 = OFF
1 = ON
Heating water flow temperature set point for the area heated
Can be set from 7 to 100°C.
Post-operation time of the generator pump
Can be set from 0 to 20 minutes
Room temperature set point in reduced mode
Can be set from 5 to 30°C.
Room temperature set point in comfort mode
Can be set from 5 to 30°C.
Circuit operating mode
0 = Timer program
1 = Manual
2 = Frost protection
Not available on this version
Not available on this version
Swimming pool water temperature set point
Can be set from 0 to 39°C
Set to 0: frost protection operation
Not available on this version
8.2.1 Modifying the User parameters
The parameters in the User menu can be modified by the user to meet his
central heating and domestic hot water comfort requirements.
according to certain system configurations,
according to the options, circuits or sensors actually connected.
Note
The name of the PCB is displayed. Check that it is actually the
PCB on which the setting must be made.
Caution
Modification of the factory settings may impair operation of the ap
pliance.
1. Access the User menu.
8 Control panel settings IniControl 2
Factory setting
Customer setting
22°C
0
40°C
4 minutes
16°C
20°C
0
20°C
EFU
31