Ultimaker 2 Extended User Manual page 26

Hide thumbs Also See for Ultimaker 2 Extended:
Table of Contents

Advertisement

4. Remove the new filament
Lower the temperature to 90 degrees (for PLA) or 110 degrees (for ABS)
Once the temperature has been reached, pull the filament out with a quick, firm pull
Check the color and shape of the tip of the filament; the goal is to have a clean, cone-shaped tip
Repeat step 3 and 4 until the filament comes out without any residue and has a cone-like shape
5. Re-assembly
Insert the bowden tube through the tube coupling collet all the way down into the PTFE coupler
Place the clamp clip around the tube coupling collet so that it secures the bowden tube