Specifications - Panasonic KX-TGP500 User Manual

Sip cordless phone
Hide thumbs Also See for KX-TGP500:
Table of Contents

Advertisement

Useful Information
Liquid damage
Problem
Liquid or other form of moisture
has entered the base unit/
handset.
Caution:
L To avoid permanent damage, do not use a microwave oven to speed up the drying process.

Specifications

■ Standard:
GAP (Generic Access Profile)
■ Frequency range:
1.88 GHz to 1.90 GHz
■ RF transmission power:
Approx. 10 mW (average power per channel)
■ Power source:
220–240 V AC, 50/60 Hz
■ Network interface:
10/100base-TX auto MDI/MDIX Ethernet LAN port
■ Support codecs:
G.722, G.711 µ-law, G.711 A-law, G.726 (32k), G.729A
■ Power consumption:
Base unit:
KX-TGP500
Standby: Approx. 1.3 W
Maximum: Approx. 2.5 W
KX-TGP550
Standby: Approx. 2.3 W
Maximum: Approx. 4.2 W
Charger:
Standby: Approx. 0.1 W
Maximum: Approx. 2.6 W
■ Operating conditions:
0 °C – 40 °C, 20 % – 80 % relative air humidity (dry)
Note:
L Design and specifications are subject to change without notice.
L The illustrations in these instructions may vary slightly from the actual product.
Trademarks
L Microsoft Excel is a registered trademark of Microsoft Corporation in the United States and/or other
countries.
L All other trademarks identified herein are the property of their respective owners.
60
Cause/solution
L Disconnect the AC adaptor and Ethernet cable from the base
unit. Remove the batteries from the handset and leave to dry for
at least 3 days. After the base unit/handset are completely dry,
reconnect the AC adaptor and Ethernet cable. Insert the
batteries and charge fully before use. If the unit does not work
properly, contact your phone system dealer.
Document Version 2012-08

Advertisement

Table of Contents
loading

This manual is also suitable for:

Kx-tgp550

Table of Contents