The following screen displays appear if you select the battery type LiXX.
The screen shows a maximum of four lines; pages 2 and 3 appear when
you move the Select arrow further down.
STORE MODE START storage mode
LiXX batteries should never be left fully charged or discharged when they
are to be stored for a protracted period, as either extreme can damage
them. Ideally they should be charged to about 60% capacity prior to sto-
rage - and that is exactly what Store mode achieves automatically by
charging or discharging the battery connected to the charger.
With the Select arrow in the store mode line (STORE MODE START), start the process by holding the ENTER button pressed in for two seconds.
Charge CHG
altered using INC or DEC. The charge current is limited to 2C by default, i.e. if you enter 2200 mAh under battery capacity in the charge memory, the
the C-rate in the Maximum charge rate (CHARGE RATE) line, where the maximum setting is 5C.
The charge current can be set to any value in the range 0.1 to 20 A, taking the maximum charge power into account. Depending on the power supply
and the battery connected to the charger, the unit may be unable to charge at the selected current, i.e. the maximum possible current may not be used
for charging. If this should occur, the screen displays the charge current actually in use.
WARNING: it is essential to observe the maximum charge current for your battery! This is generally printed on the pack itself. If you are
unsure, charge the battery at 1C (e.g. 2.2 A for a 2200 mAh battery). If the battery is charged using incorrect settings, the result could be
can reduce this value if you wish, but you cannot increase it. For example, reducing the value makes sense in very low temperatures, since a cold LiPo
battery.
With the Select arrow in the Charge (CHG) line, start the charge process by holding the ENTER button pressed in for two seconds.
Discharge DCHG
button, and altered using INC or DEC. The discharge current is limited to 2C by default, i.e. if you enter 2200 mAh under battery capacity in the charge
16

13. LiXX charge program

Storage mode
Charge
Max. capacity in x%
→ end of charge
Max. charge rate
TCS (Terminal
Capacity Selection)
11] LiPo
3S
2200mAh
Page 1
STORE MODE START
CHG.
:
2. 1 A
4.20V/C
DCHG.
:
10.0A
3.0V/C
Page 2
CUT.TEMPER. :
55°C
MAX.CAPACITY:
120%
SAFETY TIMER: 120min
CHARGE RATE :
2C
TCS CAPACITY:
Page 3
90%
TCS default: stop
TCS END ACT : CONTI.
charge process or
continue charging?
Operating Manual ULTRA DUO PLUS 80
Discharge
Cut-off temperature
Safety timer

Advertisement