Control Kit Ehs Monoblock Wiring - Samsung HHSM-G500005-1 Installation Manual

Generation 5
Hide thumbs Also See for HHSM-G500005-1:
Table of Contents

Advertisement

Terminal No.
Function
A1
230V AC Live Input
A2
230AC Neutral Input
A3
230V AC Neutral Output
A4
230V AC Live Output
B1
230V AC Neutral Output
B2
230V AC Live Output
B4
230V AC Live Output
B5
230V AC Neutral Output
B6
230V AC Live Output
B7
230V AC Neutral Output
B9
230V AC Live Output
B11
230V AC Neutral Output
B14
230V AC Live Output
B15
230V AC Live Input
B18
230V AC Live Input
B19
230V AC Neutral Output
B20
230V AC Live Output
B22
230V AC Live Input
B24
230V AC Live Input
V1
12V Input
V2
12V Input
V3
12V Input
V4
12V Input
F1
12V Comms
F2
12V Comms
Earths

Control Kit EHS Monoblock Wiring

Mains Power in 6mm² Cable
Mains Power in 6mm² Cable
Neutral Output to DHW Immersion (2.5mm² - 4mm² cable, depending on length of
cable to immersion)
Live Output to DHW Immersion (2.5mm² - 4mm² cable, depending on length of cable
to immersion)
Neutral Output to Backup Immersion Contactor or Back Up Boiler (1.5mm² cable)
Live Output to Backup immersion Contactor (1.5mm² cable)
Live Output to Backup Boiler (1.5mm² cable)
Neutral Output to Circulation Pump (1.5mm² cable)
Live Output to irculation Pump (1.5mm² cable)
Neutral Output to DHW Zone Valve (Blue Cable on DHw Zone Valve)
Live Output to DHW Zone Valve (Brown Cable on DHW Zone Valve)
Neutral output to Heating Zone Valve (Blue Cable on Heating Zone Valve 1)
Live Output to Heating Zone Valve 1 (Brown Cable on Heating Zone Valve 1)
Neutral output to Heating Zone Valve 2 (Blue Cable on Heating Zone Valve 2)
Live Output to Heating Zone Valve 2 (Brown Cable on Heating Zone Valve 2)
Neutral Output to Time Clock (1.5mm² cable)
Permanent Live to Time Clock (1.5mm² cable)
Switch Live back from Time Clock for Heating Zone 1 (1.5mm² cable)
Switch Live back from Time Clock for Heating Zone 2 (1.5mm² cable)
Input from Samsung Commissioning Controller (Wiring Cable provided with Controller)
Input from Samsung Commissioning Controller (Wiring Cable provided with Controller)
Input from Samsung Commissioning Controller (Wiring Cable provided with Controller)
Input from Samsung Commissioning Controller (Wiring Cable provided with Controller)
Communication between External Heat Pump and internal PCB (CAT 5 Shielded)
Communication between External Heat Pump and internal PCB (CAT 5 Shielded)
Connected to Earth Bar
Description
65