Control Kit Ehs Mono-Block Wiring - Samsung joule HHSM-G600005-1 Installation Manual

Table of Contents

Advertisement

Control Kit EHS Mono-block Wiring

Terminal No.
N
230V AC Neutral Output
L
230V AC Live Output
B1
230V AC Neutral Output
B2
230V AC Live Output
B4
230V AC Live Output
B5
230V AC Neutral Output
B7
230V AC Neutral Output
B8
230V AC Live Output
B10
230V AC Live Output
B14
230V AC Live Output
B15
230V AC Neutral Output
B17
230V AC Live Output
B18
230V AC Live Input
B19
230V AC Neutral Output
B20
230V AC Live Output
B22
230V AC Live Input
B24
230V AC Live Input
F1
Comms
F2
Comms
V1
12V
V2
Gnd
F3
Gnd
F4
Gnd
Earths
Function
Neutral Output to DHW Immersion
Live Output to DHW Immersion
Neutral Output to Backup Immersion Cable
Live Output to Backup immersion Cable
Live Output to Backup Boiler (1.5mm² cable)
Neutral Output to Circulation Pump (1.5mm² cable)
Neutral Output to DHW Zone Valve (1.5mm² cable)
Live Output to Circulation Pump (1.5mm² cable)
Live Output to Heating Zone Valve 1 (Brown Cable) - Where no Buffer installed
Live Output to Heating Zone Valve 2 (Brown Cable) - Where no Buffer installed
Neutral output to Heating Zone Valve (Blue Cable)
Live Output to DHW Zone Valve (Brown Cable)
Live Output to Buffer Heating Zone Valve (Brown Cable)
Neutral Output to Time Clock (1.5mm² cable)
Permanent Live to Time Clock (1.5mm² cable)
Switch Live back from Time Clock for Heating Zone 1
Switch Live back from Time Clock for Heating Zone 2
Communication to ODU
Communication to ODU
12Vdc Output
Ground
Samsung Controller
Samsung Controller
Connected to Earth Bar
Description
105

Advertisement

Table of Contents
loading

Table of Contents