ELECTRICAL WIRING (MILLIVOLT)

CONNECTING REMOTE RECEIVER

1. Set remote receiver. See instructions included in receiver kit.
2. Connect the two (2) 1/4"
female connectors to the
TP/TH and TH terminals
on the control valve.
3. Connect the four-pin
connector from the valve
motor to the four-pin con-
nector on the receiver.
4. For further instruction
refer to instruction sheet
included with RCSIT
Remote.
Do not allow wires
to touch grate or
burner.
Note: Heat reduces battery life. You can protect the receiver and extend battery life by mounting receiver
in wall or other location outside the fireplace.

ChECkING SYSTEM OPERATION

The Millivolt system and individual
components may be checked with a
Millivolt meter having a 0-1000 mV
range. Conduct each check shown in
chart below by connection meter test
leads to terminals as indicated.
A. COMPLETE MILLIvOLT SYSTEM ChECk
("A" Reading - Thermostat contacts CLOSED - Control Knob "ON" - Main burner should turn ON)
a. If the reading is more than 175 Millivolts and the automatic valve still does not come on, replace the con-
trol.
b. If the closed circuit reading ("A" reading) is less than 175 Millivolts, determine cause for low reading, pro-
ceed to Section B below.
B. Thermopile Output Reading Check
("B" Reading - Thermostat contacts OPEN - Main burner OFF)
1. Check gas pressure to the unit. If gas pressure is within minimum and maximum on data plate, then check
pilot voltage, 500 Millivolts minimum. If the minimum Millivolt reading is not obtainable, replace pilot.
22
Figure 17 -
Installing Remote Receiver
CHECK
TEST
TO TEST
COMPLETE
A
SYSTEM
THERMOPILE
B
OUTPUT
Valve
Remote Receiver
FP2010
CONNECT
remote receiver
METER LEADS
TO TERMINALS
2 & 3
1 & 2
Remote Wire
Connectors
Motor
Wires
FP2010
SWITCH OR
METER
THERMOSTAT
READING
CONTACTS
SHOULD BE
CLOSED
MINIMUM 175
OPEN
MINIMUM 500
86D0024