WARNING:
person should service and repair this insert. A qualified service person must connect and
disconnect the insert to/from the gas supply. Follow all local codes.
NOTE: This kit is designed to work manually with the dim-
mer control supplied.

BEFORE YOU BEGIN

The instruction sheet is ONLY for models listed below;
carefully inspect the contents for shipping damage. If any
parts are missing or damaged, immediately contact the dealer
from whom you purchased this kit.
This kit is designed for use with the LCUF32CR-B,
LCUF36CR-B, LCUF42CR-B fireboxes.
KIT CONTENTS:
Two (2) light socket assemblies
One (1) Rheostat dimmer
One (1) 6 ft. power cord
One (1) light join wire harness
Two (2) light bulbs (35 watt)
Two (2) light covers with clear lens
One (1) fastener pack
TOOL REQUIRED:
Phillips head screwdriver or battery drill
WARNING

Electrical Grounding Instructions:

This appliance is equipped with a three-
prong (grounding) plug for your protection
against shock hazard and should be
plugged directly into a properly grounded
three prong receptacle.
Electrical connections should only be
performed by a qualified licensed electrician.
Main power supply must be turned off
before connecting kit.
Monessen • MONAL Dual Overhead Accent Light Kit Installation Manual • 4607-904 Rev. A • 4/18
Turn appliance OFF and allow to cool before servicing. Only a qualified service
IMPORTANT: Always check local building codes.
This installation must comply with local regulations as well
as the National Electric Code.

Installation Instructions - Wiring

1. Before installing the lighting kit, wire the junction box
into an electrical circuit. This should be done before
framing the fireplace. Wire with minimum 60°C wire in
accordance with prevailing codes.
2. Remove the two (2) screws for the junction box cover,
loosen romex connector and slide up wire. Connect
wires to junction box wires securely. Slide junction box
cover down to unit and reattach to firebox and tighten
romex connector to wire. Junction box was installed at
the factory. See Figure 1.
Junction Box
Figure 1 - Junction Box Wiring Diagram
FP1912
Junction box wiring
8/08
120V AC
60Hz
Factory Supplied
Not Supplied

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MONAL and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Monessen Hearth MONAL

  • Page 1 Junction box wiring Electrical connections should only be performed by a qualified licensed electrician. 8/08 Main power supply must be turned off before connecting kit. Monessen • MONAL Dual Overhead Accent Light Kit Installation Manual • 4607-904 Rev. A • 4/18...
  • Page 2 6. Remove knob from rheostat dimmer, using two (2) screws from fastener pack, attach dimmer to side ac- cess panel. See Figure 4. Monessen • MONAL Dual Overhead Accent Light Kit Installation Manual • 4607-904 Rev. A • 4/18...
  • Page 3 Figure 6 - Light Covers Figure 7 - Rheostat Positioning Monessen, a brand of Hearth & Home Technologies 7571 215th Street West, Lakeville, MN 50044 www.monessenhearth.com Monessen • MONAL Dual Overhead Accent Light Kit Installation Manual • 4607-904 Rev. A • 4/18...

Table of Contents