Steps
8. Remove cross flow fan blade and motor
1
Remove screws fixing motor clamp and step
motor.
Remove motor clamp and step motor.
2
3
Remove screws on the joint of cross flow fan
blade and motor.
4
Remove motor.
Unplug holder of bearing ring.
5
Procedure
holder of bearing ring
screws
motor clamp
step motor
screw
motor
39