Page 5
Middle High Super High Indoor Fan Motor Rotating Speed...
Page 7
outdoor indoor filter A heat exchanger filter outdoor heat exchanger 4-way valve B heat exchanger filter high pressure switch Note: Not available for 14K/18K model discharge silencer C heat exchanger discharge temperature sensor filter D heat exchanger gas -liquid filter separator Note: Not available for 14K/18K model A1:A unit electronic expansion valve B1:B-unit electronic expansion valve...
Page 8
WARNING ROOM TEMP. TUBE TEMP. RECEIVER AND MOTOR SENSOR SENSOR DISPLAY BOARD Please don't touch any electronic component or terminal when the DISPLAY machine is running,stopping or has been powered off for less than 3 minutes to prevent electric MAGNETIC shock ! RING ROOM...
Page 10
Buttons on Remote Controller ON/OFF button +/- button MODE button button SWING button I FEEL button button SLEEP button TEMP button QUIET button ClOCK button T-ON T-OFF button TURBO button X-FAN button LIGHT button Introduction for Icons on Display Screen I feel Set fan speed Turbo mode...
Page 11
MODE button Each time you press this button , a mode is selected in a sequence that goes from AUTO,COOL, DRY, FAN, and HEAT * , as the following: *Note:Only for models with heating function. After energization, AUTO mode is defaulted. In AUTO mode, the set temperature will not be displayed on the LCD, and the unit will automatically select the suitable operation mode in accordance with the room temperature to make indoor room comfortable.(As for cooling only unit,it won’t have any action when it receives the signal of heating operation.) button...
Page 12
(1) Under Sleep 3 mode, press "Turbo" button for a long time, remote control enters into user individuation sleep setting status, at this time, the time of remote control will display "1hour ",the setting temperature "88" will display the corresponding temperature of last setting sleep curve and blink (The fi...
X-FAN button Pressing X-FAN button in COOL or DRY mode, the icon is displayed and the indoor fan will continue operation for 2 minutes in order to dry the indoor unit even though you have turned off the unit. After energization, X-FAN OFF is defaulted. X-FAN is not available in AUTO, FAN or HEAT mode. LIGHT button Press LIGHT button to turn on the display's light and press this button again to turn off the display 's light.
Before choosing the installation site,obtain user approval. Indoor unit The indoor unit should be sited in a place where: 1) the restrictions on installation specified in the indoor unit installation drawings are met. 2) both air intake and exhaust have clear paths met. 3) the unit is not in the path of direct sunlight.
Page 19
Location for securing the installation panel. Unit:mm 150cm or more Front grille Front panel 150cm or more 150cm or more...
1.Removing and installing front pane Removal method 1)Slide until the 2 stoppers click into place 2)Open the front panel forward and undo the string 3)Remove the front panel Installation method 1)Attach the front grille and front panel after pulling the string around them.
1.Refrigerant piping 1)Drill a hole ( 65mm in diameter ) in the spot indicated by the symbol in the illustration ad below . 2)The location of the hole is different depending on which side of the pipe is taken out . 3)For piping ,see6.Connecting the refrigerant pipe ,under Indoor Unit Installation(1).
2. Boring a wall hole and installing wall embedded pipe For walls containing metal frame or metal board ,be sure to use a wall embedded pipe and wall cover in the feed-through hole to Inside Outside Wall embedded pipe (field supply) Be sure to caulk the gaps around the pipes with caulking material to prevent Caulking water leakage.
4. Installing indoor unit 3 tabs 4-1.Preparation Casing Open the front panel, remove the 4 screws and dis- mount the front grille while pulling it forward. Front grille Follow the arrows to disengage the clasps on the front case to remove it. Front panel Remove Follow the procedure below when removing the slit...
Page 24
The mounting plate should be installed on a wall which can support the weight of the indoor unit. 1) Temporarily secure the mounting plate to the wall, make sure that the panel is completely level, and mark the boring points on the wall. 2) Secure the mounting plate to the wall with screws.
6.Connecting the refrigerant pipe 1)Use torque wrenches when tightening the flare nuts to prevent damage to the flare nuts and gas leaks. Open-end wrench (fixed) Coat here with refrigeration oil Flare nut Wrench Connection pipe Indoor unit tubing 2)Align the centres of both flares and tighten the flares and tighten the flare nuts 3 or 4 turns by hand. Then tighten them fully with the torque wrenches.
7.Checking for gas leakage 1)Check for leakage of gas after air purging 2)See the sections on air purges and gas leak checks in the installation manual for the outdoor unit. Check for leakage here Apply soapy water and ch- eck carefully for leaking gas. wipe soapy water off after the check is complete.
Page 27
10.Wiring With a Multi indoor unit, install as described in the installation manual supplied with the Multi outdoor unit. Live the sensor securing plate, remove the front metal plate cover, and connect the branch wiring to the terminal block. 1)Strip wire ends (15mm) 2)Mach wire colours with terminal numbers on indoor and outdoor unit’s terminal blocks and firmly screw wires to the corresponding terminals.
Page 37
Steps Procedure 1. Remove panel Pull sliding clasps at both sides of panel, pull out the panel outwards and then move the panel upwards to remove it. panel sliding clasps 2. Remove filter sub-assy Pull the damping clasps at upper/lower side of filter sub-assy, and then move the filter sub-assy filter sub-assy outwards to remove it.
Page 38
4. Remove swing parts swing parts screw Remove 2 screws fixing the swing parts, and then pull the swing parts outwards to remove it. 5. Remove water tray Remove 2 screws fixing water tray, and then pull the water tray outwards to remove it.
Page 39
7. Remove fixer of piping Pry out the clasps connecting fixer of piping and bottom case, and then pull the fixer of piping outwards to remove it. clasps fixer of piping 8. Remove evaporator Pry out the clasps connecting evaporator clasps and bottom case, and then pull the evaporator...
Page 40
10. Remove centrifugal blade Remove one nut fixing the centrifugal blade, and then pull the centrifugal blade outwards to remove it. centrifugal blade 11. Remove fixing bracket of motor Remove 3 nuts on fixing bracket of motor, and then pull the fixing bracket of motor fixing bracket outwards to remove it.
Page 42
Pipe Pipe cutter Leaning Uneven Burr Pipe Shaper Downwards Union pipe Pipe Hard mold Expander Pipe Smooth surface Improper expanding damaged leaning crack uneven surface thickness The length is equal...
Page 46
PARTS GUIDE MULTI SYSTEM SERIE MS-P-09AI, MS-P12AI, MS-P18AI...