Wired Controller XK19 Ⅰ Wired Controller XK19 1 Wired Controller XK19 It is optional for the cassette type, wall-mounted, and floor ceiling indoor units. 1.1 Outside View of the Wired Controller Fig.1 Outside View of the Wired Controller 1.2 LCD of the Wired Controller Fig.2 LCD of the Wired Controller...
Page 5
Wired Controller XK19 1.3 Introduction to the Symbols on LCD Table 1 Symbols Description Swing function. Sleep function (3 types: sleep 1,sleep2 and sleep 3). Running modes of the indoor unit (Cooling, Dry, Fan and Heating). Defrosting function for the outdoor unit. Gate-control function (this function is yet unavailable for this unit).
Page 6
Wired Controller XK19 2.2 Function of the Buttons Table 2 Name Function ① Function selection and cancellation. Enter/cancel ② Press it for 5s to examine the outdoor ambient temperature. ① Running temperature setting of the indoor unit, range:16 ~ 30℃ . ▲...
Page 7
Wired Controller XK19 3.3 Temperature Setting Press ▲or ▼ to increase/decrease the preset temperature. If press either of them continuously, the temperature will be increased or decreased by 1 ℃ every 0.5s , as shown in Fig.6. In the Cooling, Dry or Heating mode, the temperature setting range is 16 ℃~ 30 ℃ . In the Fan mode, the setting temperature is fixed at 26 ℃...
Page 8
Wired Controller XK19 Timer off setting under the “On” state of the unit is shown as Fig.8. Fig. 8 Timer off Setting under the “On” State of the Unit Timer range: 0.5-24hr. Every press of ▲or ▼ will make the set time increased or decreased by 0.5hr. If either of them is pressed continuously, the set time will increase/ decrease by 0.5hr every 0.5s.
Page 9
Wired Controller XK19 Fig. 9 Swing Setting Note: Sleep, Save, Turbo, Blow or Quiet setting is the same as the Swing setting. ① . After the setting has been done, it has to press the key “Enter/cancel” to back to the setting status or ②...
Page 10
Wired Controller XK19 Fig. 10 Sleep Setting Sleep off is default after power failure and then power recovery, and the sleep functions is unavailable under the fan mode. There are three Sleep modes: Sleep 1, Sleep 2 and Sleep 3. a.
Page 11
Wired Controller XK19 / ( ℃ ) Time/(Hr) Fig.11 Sleep Curve of Sleep 2 in Cooling Mode In the Heating mode, the temperature may be set at 16 ℃ or between 17 ℃ - 20 ℃ , 21 ℃ -27 ℃ or 28 ℃ - 30 ℃...
Page 12
Wired Controller XK19 For example, the temperature in the Heating mode is set at 22 ℃ .Under the mode of Sleep2, the temperature will decrease by 1 ℃ every 1hr. After it decreases by 2 ℃ in total, i.e. 20 ℃ ,the unit will keep running at 20 ℃...
Page 13
Wired Controller XK19 When the Turbo function is activated, press Function to enter the Turbo setting interface and then press Enter/Cancel to cancel this function. Turbo function setting is as shown in Fig.14. Fig.14 Turbo Setting Notes: When the Turbo function is activated, if the difference between the room temperature and set ①...
Page 14
Wired Controller XK19 Fig. 15 Saving Setting for Cooling Save Setting for Heating: Under on state or in the Heating mode of the unit, press Function to enter the Save setting interface and then press ▲or ▼ to adjust upper limited value in the Heating mode. After that, press Enter/Cancel to activate the Save function for heating.
Page 15
Wired Controller XK19 Fig.16 Save Setting for Heating Notes: If press Function on the Save setting interface or if there is not any operation for 5s after last button ① . press, the Save setting will be canceled automatically by the system, with memorizing the present setting data. When power is on after the power failure, the Save function will be memorized.
Page 16
Wired Controller XK19 Fig.17 E-heater Setting 3.11 Blow Setting Blow function: After the unit is turned off, the water in evaporator of indoor unit will be automatically evaporated to avoid mildew. In the Cooling or Dry mode, press Function till the unit enters the Blow setting interface and then press Enter/Cancel to active this function.
Page 17
Wired Controller XK19 Fig.18 Blow Setting Notes: When the Blow function is activated, if turning off the unit by pressing On/Off or by the remote ① . controller, the indoor fan will run at the low fan speed for 10 min, with “BLOW” displayed on the LCD. While, if the Blow function is deactivated, the indoor fan will be turned off directly.
Page 18
Wired Controller XK19 Fig.19 Quiet Setting Notes: When the Quite function is activated, the fan speed is low and un-adjustable. ① . When the Auto Quite function is activated, the unit will run according to the difference between the ② . room temperature and the setting temperature.
Page 19
Wired Controller XK19 Memory recovery: If this function has been set for the wired controller, the wired controller after power failure will resume its original running state upon power recovery. Memory contents: On/Off, Mode, set temperature, set fan speed, Save function and Lock function. c.
Page 20
Wired Controller XK19 Table 3 Meaning of Each Error Error Error Code High pressure protection Low pressure protection Discharge protection Over-current protection Communication error Indoor water overflow protection Mode conflict Anti-freezing protection Defrosting or oil returning for heating Indoor ambient temperature sensor open/short circuit Evaporator temperature sensor open/short circuit Indoor unit (liquid valve) refrigerant pipe inlet temperature sensor error Indoor unit (gas valve) refrigerant pipe outlet temperature sensor error...
Page 21
Wireless Remote Controller YT1F Ⅱ Wireless Remote Controller YT1F Notes: Be sure that there are no obstructions between the receiver and the remote controller; ① . Do not drop or throw the remote controller; ② . Do not let any liquid into the remote controller and expose the remote controller to direct sunlight or ③...
Page 22
Wireless Remote Controller YT1F 4) FAN Auto, Low, Middle, or High fan speed can circularly selected by pressing this button. After powered on, the default is Auto speed. Under Dehumidifying mode, only Low fan speed is available. 5) CLOCK The clock can be set up by pressing this button, with the symbol displayed and blinking.
Page 23
Wireless Remote Controller YT1F This kind of remoter controller is universal. And the three swing statuses of are the same as that of If the swing function is deactivated when the air guide louver is swing up and down, it will stop at the current position.
Page 24
Wireless Remote Controller YT1F BLOW OFF: When press the ON/OFF button to turn off the unit, the whole unit will be stopped ② . completely. b. About AFTERHEAT BLOW Under the Heat mode or Auto Heat mode, if the unit is turned off, the compressor and outdoor fan will stop running immediately and the upper and lower guide board will rotate to the horizontal position, while the indoor fan will still run at the low fan speed.
Contents Ⅰ Safety Information ....................1 Ⅱ Selection of Installation Location and Precautions ..........2 1 Selection of Installation Location for Air Conditioner Unit ......... 2 2 Selection of Installation Location ................. 2 3 Caution for installation where air conditioner trouble is likely to occur ...... 2 Ⅲ...
Ⅰ Safety Information Please read this manual carefully before use this unit, and operate it correctly according to the guide in this manual. Please take specially note to the meaning of these two marks : Warning! This mark means that it may cause casualty or badly hurt if the operation is incorrect. Caution! This mark means that it may cause casualty or property loss if the operation is incorrect.
Ⅱ Selection of Installation Location and Precautions 1 Selection of Installation Location for Air Conditioner Unit The installation of air conditioner unit must be in accordance with national and local safety codes. Installation quality will directly affect the normal use of air conditioner unit. The user is prohibited from installation by himself.
Ⅲ Installation of Floor And Ceiling Type Indoor Unit 1 Space dimension for installation of the unit The space around the unit is adequate for ventilation. (Refer to Fig.1) Fig.1 2 Important notice a. The unit must be installed by the professional personnel according to this install instruction to ensure the well use.
Page 29
* Loosen two hanger bracket setting bolts (M8) on eath side for less than 10mm. Remove two hanger bracket fixing bolts (M6) on the rear side. Detach the hanger bracker by pulling it backward (Refer to Fig.5). Fig.2 Fig.3 c. Set the suspension bolt. (Use W3/8 or M10 size suspension bolts) *...
Page 30
When installing the indoor unit, you can refer the paper pattern for installation, and make sure that the drainage side must be 10mm lower than the other side in order to drain the condensation water fluently. Unit:mm Model MC-F09AI MC-F12AI 1220 1158...
4 Electrical wiring Caution: The power of every indoor unit should be connected in outdoor unit. a. Open surface panel. b. Remove the electrical box cover. c. Route the power connection cord from the back of the indoor unit and pull it toward the front through the wiring hole upward.
MC-E36AI POWER INDOOR UNIT C INDOOR UNIT A INDOOR UNIT D INDOOR UNIT B XT5X XT3X OUTDOOR UNIT Caution ! T he incorrect of wiring connecting would lead malfunction of some of the electric elements. ① . M ake sure that the lead between the connect end and the clamp end has some need space after the ②...
Cramp⑤ Large seeing pad⑤ (Accessory) (Accessory) Air outlet Watering can Fig.12 Fig.13 Fig.14 6 Install the connection pipes Connect the connect pipe with the two relative leading pipe, tie the nut on tie–in of the connect pipe tightly. Caution ! *...
Ⅳ Constitutes and Names of Every Part of Floor And Ceiling Type Indoor Unit Air outlet Guide louver Surface Panel Air filter, purifier (in air inlet grille) Connecting pipe Air inlet Suitable model : MC-F09AI, MC-F12AI, MC-F18AI, MC-F24AI Note:The appearances will be same by the different models of air conditioners.
Ⅴ Working Temperature Range Working Temperature Range Indoor side state Outdoor side state Dry bulb temp. ℃ Wet bulb temp. ℃ Dry bulb temp. ℃ Wet bulb temp. ℃ Rated. Cooling Max. cooling Min. cooling — Rated. Heating Max. heating —...
Ⅵ Maintenance Method Warning! D o turn off the unit and cut off the main power supply when cleaning the air conditioner, otherwise ① . electric shock may happened. D o not make the air conditioner wet or electric shock may be lead; Ensure that the air conditioner will ②...
Ⅶ Operating Instructions * The temperature should not be set lower * To distribute cool air throughout the room, than what you need. This would lead to increase adjust airflow direction as shown by the arrows energy cost. (see picture) to diffuse cool air. *...
Page 38
* Check electrical system (voltage and frequency). Use the power supply indicated * Turn off the air conditioner if, while the air on the unit to operate the air conditioner and conditioner is running, electricity interference only fuses with specified capacity it should be occurs.
Ⅷ Malfunction Analyzing Warning ! Do not repair air conditioner by yourself for the incorrect repair would lead electric shock or fire. Please contact service center and had the unit repaired by specialized personnel. Check the following item before contacting to repair could save your time and cost. Malfunction Phenomena Malfunction Analyzing The air conditioner can’t start...