Sinclair MS-H07AIC PT User Manual

Multi system-wall mounted
Hide thumbs Also See for MS-H07AIC PT:

Advertisement

Quick Links

USER'S MANUAL
MULTI SYSTEM-wall mounted
MS-H07AIC PT, MS-H09AIC PT
MS-H12AIC PT, MS-H18AIC PT

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MS-H07AIC PT and is the answer not in the manual?

Questions and answers

Summary of Contents for Sinclair MS-H07AIC PT

  • Page 1 USER'S MANUAL MULTI SYSTEM-wall mounted MS-H07AIC PT, MS-H09AIC PT MS-H12AIC PT, MS-H18AIC PT...
  • Page 2 “Original instructions”   Thank you for choosing Residential Air Conditioners, please read this owner’s manual carefully before operation and retain it for future reference.
  • Page 3 MS-H07AIC PT MS-H09AIC PT MS-H12AIC PT MS-H18AIC PT...
  • Page 4: Table Of Contents

    CONTENTS Operation and maintenance ■ ............1 Notices for operation ■ ..............3 Notices for use ■ ...........5 Names and functions of each part ..........6 ■ Operation of Remote Controller ■ ............12 Emergency operation ■ ..............13 Clean and care ■ ..............15 Troubleshooting Installation service ■...
  • Page 5: Notices For Operation

    Notices for operation Please read the following carefully before operating Be sure to pull out ★ When the voltage ★ Never splice the is very high, the the power plug as power cord or use components would be easily the air conditioner not in use an extended cord.
  • Page 6 Notices for operation ★ ★ Please don't cut off or damage the To adjust the airflow direction power cords and control cords. appropriately. When operating the unit,to adjust the vertical and lateral air If they are damaged, please ask the qualified flow direction by use of remote controller.
  • Page 7: Notices For Use

    Notices for use Working principle and special functions for cooling Principle: Air conditioner absorbs heat in the room and transmit to outdoor and discharged, so that indoor ambient temperature decreased, its cooling capacity will increase or decrease by outdoor ambient temperature. Anti-freezing function: If the unit is running in COOL mode and in low temperature, there will be frost formed on the heat exchanger, when indoor heat exchanger temperature decreased below 0 , the...
  • Page 8: Working Temperature Range

    Notices for use Working temperature range Indoor sideDB/WB( Outdoor sideDB/WB( Maximum cooling 32/23 43/26 Maximum heating 27/--- 24/18 The operating temperature range (outdoor temperature) for cooling only unit is 18℃~ 43℃; for heat pump unit is -7℃~ 43℃.
  • Page 9: Names And Functions Of Each Part

    Names and functions of each part Air in ⑵ ⑹ ⑸ ⑷ Air out ⑶ The pattern in displayer: ⑴ :Cool :Dry :Fan :Heat ⑴ Remote controller : ⑵ Front panel :Set temp. ⑶ Filter ⑷ Guide louver ⑸ Wall pipe ⑹...
  • Page 10: Operation Of Remote Controller

    Operation of Remote Controller ON/OFF Press it to start or stop operation. : Press it to decrease temperature setting. : Press it to increase temperature setting. Press it to set fan speed. MODE Press it to select operation mode (AUTO/COOL/DRY/FAN/HEAT). I FEEL(Page 9) Press it to set HEALTH function Press it to set AIR function.
  • Page 11: Digital Display

    Operation of Remote Controller 19 20 21 22 MODE icon: LIGHT icon: If MODE button is pressed, is displayed by pressing the current operation mode icon LIGHT button. Press LIGHT button again to clear the display. (AUTO), ( COOL), (DRY), (FAN) or (HEAT LOCK icon:...
  • Page 12 Operation of Remote Controller 19 20 21 22 AIR icon: HEALTH icon: is displayed when pressing the is displayed when pressing the AIR button.Press this button again HEALTH button. Press this button to clear the display. again to clear the display. (Optional for some models.) I FEEL icon: X-FAN icon:...
  • Page 13 Operation of Remote Controller Remote Controller Description ON/OFF : Press this button to turn on the unit .Press this button again to turn off the unit. Press this button to decrease set temperature. Hold it down for above 2 seconds to rapidly decrease set temperature.
  • Page 14 Operation of Remote Controller TIMER ON : Press this button to initiate the auto-ON timer. To cancel the auto-timer program, simply press this button again. After pressing this button, disappears and "ON "blinks . 00:00 is displayed for ON time setting.
  • Page 15 Operation of Remote Controller SLEEP : Press this button to go into the SLEEP operation mode. Press it again to cancel this function. This function is available in COOL, HEAT (Only for models with heating function) mode to maintain the most comfortable temperature for you. LIGHT: Press LIGHT button to turn on the display's light and press this button again to turn off is displayed.
  • Page 16: Emergency Operation

    Emergency Operation Emergency Operation When the remote controller is lost or damaged, please use the manual switch on the main unit. In that case, the unit will operate in AUTO mode and the temperature setting or fan speed can not be changed.
  • Page 17: Clean And Care

    Clean and care Caution Turn power off and pull out the power plug before cleaning air conditioner, or it may cause electric ● shock. Never sprinkle water on the indoor unit and the outdoor unit for cleaning because it can cause an ●...
  • Page 18 Clean and care Check before use ① Be sure that nothing obstructs the air outlet and intake vents. ② Check that whether ground wire is properly connected or not. ③ Check that whether the batteries of air conditioner are changed or not. Maintain after use ①...
  • Page 19: Troubleshooting

    Troubleshooting CAUTION Don't attempt to repair the air conditioner by yourself, it can cause an electric shock or fire. Please check the following items before asking for repair, it can save your time and money. Phenomenon Troubleshooting Not operate immediately when the air Once the air conditioner is stopped, it will ●...
  • Page 20 Troubleshooting Phenomenon Troubleshooting Has the power been shut down? ● The unit can not run. Is power plug loosed? ● ● Is the circuit protection device tripped off or not? Is voltage higher or lower? ● (Tested by professionals) Breaking off Is the TIMER correctly used? ●...
  • Page 21 Troubleshooting Phenomenon Troubleshooting Indoor unit cannot deliver air. In HEAT mode, when the temperature of indoor ● heat exchanger is very low, that will stop deliver air in order to prevent cool air. (Within 2min) ● In HEAT mode, when the outdoor temperature is low or high humidity, there are much frost be formed on the outdoor heat exchanger, that the unit will automatically defrost, indoor unit stop...
  • Page 22: Notices For Installation

    Notices for installation Important Notices 1. The unit installation work must be done by qualified personnel according to the local rules and this manual. 2. Before installation, please contact with local authorized maintenance center, if unit is not installed by the authorized maintenance center, the malfunction may not solved, due to discommodious contacts.
  • Page 23 Notices for installation Safety Requirements For Electric Appliances The power supply should be used the rated voltage and AC exclusive circuit, the power cable diameter should be satisfied. 2. Don't drag the power cable emphatically. It should be reliably earthed, and it should be connected to the special earth device, the installation work should be operated by the professional.
  • Page 24: Installation Dimension Diagram

    Installation dimension diagram Installation dimension diagram Space to the ceiling 15cm Above Space to the wall 15cm Above 15cm Above Space to the wall 300cm Above Above Air outlet side Space to the floor The dimensions of the space necessary for correct ●...
  • Page 25: Install Indoor Unit

    Install indoor unit Install of Mounting Plate 1. Mounting plate should be installed horizontally. As the water tray's outlet for the indoor unit is two-way type, during installation, the indoor unit should slightly slant to water tray's outlet for smooth drainage of condensate.
  • Page 26 Install indoor unit Install of Drain Hose Connect the drain hose to the outlet pipe of the indoor unit. Bind the joint with rubber belt. outlet pipe of indoor unit outlet pipe of drain hose indoor unit rubber belt Put the drain hose into insulating tube. outlet pipe of drain hose indoor unit...
  • Page 27: Install The Indoor Unit

    Install indoor unit NOTE: When connecting the electric wire if the wire length is not enough, please contact with the authorized service shop to buy a exclusive electric wire that is long enough and the joint on the wire are not allowed. The electric wiring must be correctly connected, wrong connection may cause spare parts ●...
  • Page 28: Check After Installation And Test Operation

    Check after installation and test operation Check after installation Items to be checked Possible malfunction Has it been fixed firmly? The unit may drop, shake or emit noise. It may cause insufficient cooling(heating) Have you done the refrigerant leakage test? capacity It may cause condensation and dripping.
  • Page 29: Installation And Maintenance Of Healthy Filter

    Installation and Maintenance of Healthy Filter Installation Instructions 1. Forcibly pull the panel for a specific angle from the two ends of the front panel according to the arrow direction. Then pull the air filter downwards to remove it. (See Fig.a) Fig.
  • Page 30: Configuration Of Connection Pipe And Additional Volume Of Refrigerant

    Configuration of connection pipe and additional volume of refrigerant 1. Standard length of connection pipe 5m、7.5m、8m 2. Min length of connection pipe For the unit with standard connection pipe of 5m, there is no limitation for the min length of connection pipe. For the unit with standard connection pipe of 7.5m and 8m, the min length of connection pipe is 3m.
  • Page 31 Configuration of connection pipe and additional volume of refrigerant Sheet 2. Additional refrigerant charging amount for R410A Diameter of connection pipe mm Indoor unit throttle Outdoor unit throttle Liquid pipe Gas pipe Cooling only, Cooling only Cooling and cooling and heating (g / m) heating (g / (g / m)
  • Page 32 185/2001 Coll., in the wording of later regulations. In case of incorrect disposal of this waste, a fine can be imposed according to national regulations. Manufacturer: Sinclair Corporation Ltd., 1-4 Argyll Street, London W1F 7LD, UK Supplier and technical support: Nepa, spol.s.r.o.

This manual is also suitable for:

Ms-h09aic ptMs-h18aic ptMs-h12aic pt

Table of Contents