The Model 1824 is prewired for a 220V power supply, but
it can be rewired to operate on a 110V power supply. To
reduce the risk of electrocution, machine damage, or an
electrical fire, this procedure must be performed by an
electrician or qualified service personnel. The procedure
involves moving terminal jumpers inside the motor
junction box, replacing the machine circuit breaker, and
replacing the plug on the power cord.
The require machine circuit breaker can be purchased
from an authorized Shop Fox dealer. The required
plug and receptacle can be purchased from your local
hardware store or it may be provided by your electrician.
Items Needed
Phillips Screwdriver #2 .........................................1
NEMA 5-20 Plug ..................................................1
Circuit Breaker 20A (Part No. X1824204-1) .................1
To convert the table saw to 110V, do these steps:
1. DISCONNECT TABLE SAW FROM POWER!
2. Open the motor junction box, then loosen the four
screws indicated in Figure 4.
3. Remove the two center jumpers (they are stacked
together), reposition them as shown in Figure 5,
then re-tighten the four screws loosened in Step 2.
4. Close and secure the motor junction box.
5. Remove the START/STOP switch box from the switch
mounting plate.
6. Replace the pre-installed 10A circuit breaker
(see Figure 6) with the 20A circuit breaker, then
re-install the switch box.
7. Replace the existing power cord plug with a NEMA
5-20 plug, according to the instructions and wiring
diagram provided by the plug manufacturer.
This manual was current at the time of printing.
However, if the motor wiring diagram provided on
the inside of the junction box cover differs from this
manual, always use the junction box cover wiring
diagram. This should reflect any changes that may
have occurred after printing.
Motor Rewired
for 110V
(As Recommended)
Model W1824 10" Hybrid Table Saw
Motor Prewired
for 220V
Ground
Qty
Figure 4. Locations of screws to be
Rewired for 110V
Motor Rewired
for 110V
New Jumper Locations
Figure 5. Relocated jumpers.
Figure 6. Location of switch circuit
-12-
200MFD
60MFD
250VAC
300VAC
Neutral
110V/220V
Hot
MOTOR
Ground
Rewired for 110V
Loosen
These
Screws
Ground
Center Jumpers
loosened.
Ground
Rewired for 110V
Circuit
Breaker
breaker.
Ground
Hot
Hot
Motor Prewi
for 220V

Advertisement