The IBM xSeries 130 model 8672 appliance server

This section provides general information about the model 8672 appliance server.

Features and specifications

The following table provides a summary of the features and specifications for the
xSeries 130 model 8672 appliance server.
Microprocessor:
One Intel Celeron
800 MHZ
microprocessor with MMX™
(MMX2) technology
128 KB Level-2 cache
Memory:
Standard: 256 MB
Maximum: 1.5 GB
Type: PC133 MHz, ECC SDRAM,
unregistered DIMMs only
Slots: Three dual inline
Supports 128 MB, 256 MB, and
512 MB DIMMs
Drives:
Diskette: 1.44 MB
CD-ROM: 24-10X IDE
One 20 GB IDE hard disk drive
Supports two 40 GB IDE hard
disk drives maximum
Expansion bays:
Two 3.5 inch slim-high bays for IDE
hard disk drives (one available)
Power supply:
One 200 watt (110 or 220 V ac auto-
sensing) with Wake on LAN® support
Table 2. Features and specifications for the xSeries 130 model 8672.
8
IBM xSeries 130: User's Reference
Video:
S3 Savage 4 Pro video
controller on the system board
Compatible with SVGA and VGA
8 MB SDRAM video memory
Size:
Height: 4.37 cm (1.75 in.)
Depth: 63.5 cm (25 in.)
Width: 44 cm (17.32 in.)
Maximum weight: 19.05 kg (42
lb) depending on your
configuration
Integrated functions:
Dual-channel bus mastering IDE
controller
Dual 10BASE-T/100BASE-TX
Ethernet controllers on the
system board with Alert on
LAN
2 support
One serial port
Two Universal Serial Bus (USB)
ports
Keyboard port
Mouse port
Acoustical noise emissions:
Sound power, idling: 6.6 bel
maximum
Sound power, operating: 6.8 bel
maximum
Environment:
Air temperature:
— Server on: 10° to 35° C (50.0°
to 95.0° F). Altitude: 0 to 914
m (2998.7 ft)
— Server on: 10° to 32° C (50.0°
to 89.6° F). Altitude: 914 m
(2998.7 ft) to 2133 m (6998.0
ft)
— Server off: -40° to 60° C
(-104° to 140° F). Maximum
altitude: 2133 m (6998.0 ft)
Humidity:
— Server on: 8% to 80%
— Server off: 5% to 100%
Heat output:
Approximate heat output in British
thermal units (Btu) per hour
Minimum configuration: 171 Btu
(50 watts)
Maximum configuration: 410 Btu
(120 watts)
Electrical input:
Sine-wave input (47-63 Hz)
required
Input voltage low range:
— Minimum: 90 V ac
— Maximum: 137 V ac
Input voltage high range:
— Minimum: 180 V ac
— Maximum: 265 V ac
Input kilovolt-amperes (kVA)
approximately:
— Minimum: 0.09 kVA
— Maximum: 0.21 kVA