The IBM xSeries 130 model 8654 appliance server
This section provides general information about the model 8654 appliance server. For
information about the model 8672, see "The IBM xSeries 130 model 8672 appliance
server" on page 8.
Features and specifications
The following table provides a summary of the features and specifications for the
xSeries 130 model 8654 appliance server.
Microprocessor:
®
®
•
One Intel
Pentium
microprocessor with MMX™
technology and SIMD
extensions
•
256 KB level-2 cache
•
Supports up to two 1 GHZ
microprocessors
Memory:
•
Standard: 256 MB
•
Maximum: 2 GB
•
Type: PC133 MHz, ECC
SDRAM, registered DIMMs
•
Slots: Four dual inline
•
Supports 128 MB, 256 MB, 512
MB, and 1 GB DIMMs
Drives:
•
Diskette: 1.44 MB
•
CD-ROM: 24-10X IDE
•
One 18.2 GB 10K SCSI hard
disk drive
•
Supports two 36 GB 10K SCSI
hard disk drives maximum
Expansion bays:
Two 3.5-inch slim-high bays for SCSI
hard disk drives (one available)
PCI expansion slots:
Two 33 MHz, 64-bit
Power supply:
One 200 watt (115-230 V ac)
Table 1. Features and specifications for the xSeries 130 model 8654.
Video:
III 1 GHZ
•
S3 video controller on the system
board
•
Compatible with SVGA
•
8 MB SDRAM video memory
Size:
•
Height: 4.37 cm (1.75 in.)
•
Depth: 63.5 cm (25.72 in.)
•
Width: 43.9 cm (17.32 in.)
•
Weight: approximately 12.7 kg
(28 lb) when fully configured
Integrated functions:
•
One Ultra160 SCSI controller
•
Dual 10BASE-T/100BASE-TX
Intel Ethernet controllers on the
system board
•
One serial port
•
Two Universal Serial Bus (USB)
ports
•
Advanced System Management
(ASM) processor
•
Two RS-485 ASM ports (one in,
one out)
•
Two C2T ports (one in, one out)
Acoustical noise emissions:
•
Sound power, idling: 6.1 bel
maximum
•
Sound power, operating: 6.2 bel
maximum
Environment:
•
Air temperature:
— Server on: 10° to 35° C (50.0°
to 95.0° F). Altitude: 0 to 914 m
(2998.7 ft)
— Server on: 10° to 32° C (50.0°
to 89.6º F). Altitude: 914 m
(2998.7 ft) to 2133 m (6998.0
ft)
— Server off: 10° to 43° C (50.0°
to 109.4° F). Maximum altitude:
2133 m (6998.0 ft)
•
Humidity:
— Server on: 8% to 80%
— Server off: 8% to 80%
Heat output:
Approximate heat output in British
thermal units (Btu) per hour
•
Minimum configuration: 273 Btu
(80 watts)
•
Maximum configuration: 751 Btu
(220 watts)
Electrical input:
•
Sine-wave input (50-60 Hz)
required
•
Input voltage low range:
— Minimum: 100 V ac
— Maximum: 127 V ac
•
Input voltage high range:
— Minimum: 200 V ac
— Maximum: 240 V ac
•
Input kilovolt-amperes (kVA)
approximately:
— Minimum: 0.08 kVA
— Maximum: 0.22 kVA
Chapter 1. Introduction
5