Download Print this page
Anest Iwata WA 101 Instruction Manual

Anest Iwata WA 101 Instruction Manual

Automatic spray gun

Advertisement

Quick Links

ANEST IWATA Europe S.r.l.
Corso Vigevano, 46 - 10155, Torino (Italy)
Direct Tel. +39 011 - 22 74 402
Fax +39 011 - 22 74 000
info@anest-iwataeu.com
www.anest-iwataeu.com
ANEST IWATA Italia S.r.l.
Corso Vigevano, 46 - 10155, Torino (Italy)
Tel. diretto +39 011 - 24 80 868 - Fax: +39 011 - 85 19 44
info@anest-iwata.it
www.anest-iwata.it
ANEST IWATA Iberica
Calle de Les Teixidores, 3-5
08918 - Badalona (Barcelona)
Tel.:+34 93 32 05 993 - Fax.:+34 93 32 05 965
info@anest-iwata.es
www.anest-iwata.es
ANEST IWATA Deutschland
Mommsenstrasse 5
04329 Leipzig
Telefon: +49 (0)341 241 44 30 - Fax: +49 (0)341 252 55 95
info@anest-iwata.de
www.anest-iwata.de
European Sales Branches:
ANEST IWATA Scandinavia
Ögärdesvägen 6C, 433 30 PARTILLE - Sweden
Tel. +46 (0)31 - 340 28 60 - Fax +46 (0)31 - 340 28 69
info@anest-iwata.se
www.anest-iwata.se
ANEST IWATA France
25 rue de Madrid - 38070 St Quentin Fallavier - France
Tél. +33 (0)4 - 74 94 59 69 - Fax +33 (0)4 - 74 94 34 39
info@anest-iwata.fr
www.anest-iwata.fr
ANEST IWATA U.K.
Unit 10 Little End Road - Eaton Socon
St. Neots - CAMBRIDGESHIRE
PE19 8JH
Tel.: +44 (0) 1480 40 54 19 Fax: +44 (0) 1480 21 76 10
enquiries@anest-iwata.co.uk
www.anest-iwata.co.uk
WA 101/WA 200/WA 200WB AUTOMATIC SPRAY GUN
WA 101R ROUND PATTERN AUTOMATIC SPRAY GUN
LPA 200 HVLP AUTOMATIC SPRAY GUN
Before use, adjustment or maintenance, it is important to read
GB
this instruction manual very carefully. This manual must be stored
in a safe place for any future reference that may be necessary.
This ANEST IWATA spray guns kit complies to ATEX regulations 94/9/EC, protection level:
II 2 G X Suitable for using Zones 1 and 2.
X marking. Any static electricity discharge from the spray gun is to be diverted to the ground via the conductive air hose as stipulated.
IMPORTANT
This automatic spray gun should be operated only by an adequately trained operator for safe use and maintenance of the equip-
ment. Any misuse or handling other than those indicated in this Instruction Manual is not covered by guarantee.
ANEST IWATA disclaims all responsibility for any accident or damage caused by failure observing the operational and safety pro-
cedures in this manual. In the interest of user friendliness, this manual contains information in a brief and concise form.
For any additional information you may require regarding the automatic spray gun operations, or if any missing parts or any dam-
age during transportation is found, or details of training courses, please contact your nearest ANEST IWATA Company (see last
cover page).
Be sure to observe warnings and cautions in this instruction manual.
If not, it can cause paint ejection and serious bodily injury by drawing organic solvent.
Be sure to observe following
marked items which are especially important.
WARNING Indicates a potentially hazardous situation which, if not avoided, may result in serious injury or loss of life.
CAUTION
Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury or pro-
perty damage.
IMPORTANT
Indicates notes which we ask you to observe. The safety precautions in this instruction manual are the mini-
mum necessary conditions. Follow national and local regulations regarding fire prevention, electricity and
safety as well as your own company regulations.
Manufactured by:
ANEST IWATA Corporation 3176,Shinyoshida-cho, Kohoku-ku, Yokohama, 223-8501 Japan
Instruction Manual

Advertisement

loading
Need help?

Need help?

Do you have a question about the WA 101 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Anest Iwata WA 101

  • Page 1 Any misuse or handling other than those indicated in this Instruction Manual is not covered by guarantee. ANEST IWATA disclaims all responsibility for any accident or damage caused by failure observing the operational and safety pro- cedures in this manual. In the interest of user friendliness, this manual contains information in a brief and concise form.
  • Page 2: Spare Parts List

    PARTS LIST WA-200WB-101P 1.0 (0.039) 1.6 (31) 340 (12.1) WA-200WB-121P 1.2 (0.047) 380 (14.9) Ref.part Description WA 101 WA 101R WA 200/WA 200WB LPA 200 MODEL FLUID NOZZLE Fluid needle WA-200WB-141P 1.4 (0.055) 340 (13.4) Orifice Mark Air cap set WA-200WB-161P 1.6 (0.063)
  • Page 3: Troubleshooting

    SAFETY WARNINGS TROUBLESHOOTING Spray Pattern Problems Remedies IMPROPER USE OF EQUIPMENT 1. Air enters between fluid nozzle and 1. Remove fluid nozzle to clean seat. Fluttering tapered seat of gun body. If it is damaged, replace nozzle. 2. Air is drawn from fluid needle packing set 2.
  • Page 4 Replace if it is deformed or worn out. Set the spray distance from the gun to the work piece as near as possible within the range of 150_200 mm (5.9 to 7.9 in) with WA 101/101R, 3. Leakage from seat section between fluid nozzle and fluid needle set Replace them if leakage does not stop after fully cleaning fluid nozzle and 200_250 mm (7.9 to 9.8 in) with WA 200/WA 200WB, and 100_200 mm (3.9 to 7.9 in) with LPA 200.

This manual is also suitable for:

Wa 200Wa 200wbWa 101rLpa 200 hvlp