Be sure to observe warning s and cauti o ns i n this instructi o n manual.
If not, it can cause paint ejecti o n and seri o us bodily i n jury by drawi n g organic solvent.
Be sure to observe fol l owing
marked items which are especially important .   
Indicates a potentially hazardous situation which, if not avoided, may result in serious injury or loss of
life.
Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury
or property damage.
Indicates notes which we ask you to observe. The safety precautions in this instruction manual are
the minimum necessary conditions. Follow national and local regulations regarding fire prevention,
electricity and safety as well as your own company regulations.
IMPORTANT WARNING: Our spray guns, airbrushes, and other products are made to conform by our local group companies with local laws and regulations
that may differ from place to place. Improper trade of products outside of designated domestic territories (unauthorized reselling) can result in legal violations,
local fines, and penalties. ANEST IWATA CORPORATION assumes no liability for products acquired through unauthorized reselling and in such cases and due
to quality control protocols, unauthorized reselling renders the warranty null and void.
Symbol Marking on the Spray Gun:
This ANEST IWATA spray gun
complies with 2014/34/EU Directive
relating to equipment and protective
systems intended for use in explosive
potentially atmospheres.
Important specifications
Max. Pressure
Noise level
Spray condi t i o n
Measuri n g point
Max. temperature
Important
Never connect pressure feedi n g pai n t except pressure feed type spray gun.
Main specifications
Nozzle orifice
Model
Type of feed
WIDER1-08E2P
0.8 (0.031)
-10E2P
1.0 (0.039)
Pressure
-13E2P
1.3 (0.051)
-15E2P
1.5 (0.059)
WIDER1-10E1S
1.0 (0.039)
-13K1S
-13H2S
1.3 (0.051)
-13H4S
Suction
-15K1S
1.5 (0.059)
-15H2S
-18N1S
1.8 (0.071)
WIDER1-10E1G
1.0 (0.039)
-13K1G
-13H2G
1.3 (0.051)
-13H4G
Gravity
-15K1G
1.5 (0.059)
-15H2G
-18N1G
1.8 (0.071)
*1. Atomizing air pressure means air pressure at spray gun inlet when trigger is pulled and air flows.
II 2 G Ex h X
II
Complies
Specific
Group II
with
Marking for
(Surface)
European
Explosion
Directive
Protective
0.70MPa / 7.0bar / 100psi
79dB(A)
Recommended
1m backwards from spray gun, 1.6m height
Atmosphere: 5°C ~40°C (41°F~104°F)
Air cap assy
*1 Atomizing air
Mark
pressure
mm (in)
MPa (bar / PSI)
0.29
(3.0 / 43)
E2P
0.24
E1
(2.5 / 36)
K1
H2
H4
0.2 (2.0 / 28)
K1
H2
N1
0.24
(2.5 / 36)
E1
K1
H2
H4
0.2 (2.0 / 28)
K1
0.24
H2
(2.5 / 36)
N1
2
G
Ex h
Category
Type of
Ignition
(Zone 1&2)
Atmosphere
Protection
(GAS)
(not applied)
Air and Fl u id: 5°C ~43°C (41°F~109°F)
Recommended condition
Fluid output
ml/min
150
200
250
85
150
140
175
170
210
95
160
155
200
190
240
1
This manual contains IMPORTANT
WARNINGS and INSTRUCTIONS.
Equipment in this manual is exclusively for
painting purposes.
Do not use for other purposes.
The operator shall be fully conversant with
the requirements stated in this instruction
manual including important warnings,
cautions and operation and correct handling.
Read and understand the instruction
manual, before use and retain for reference.
IIB
T6
Gb
Explosion
Temperature
Explosion
Group
Class
Protection
(Ethylene)
( 85°C)
level
(EPL)
Nozzl e needle assy combinati o n
Fluid nozzl e
Orifice mm (i n )
0.8 (0.031)
1.0 (0.039)
1.3 (0.051)
1.5 (0.059)
1.8 (0.071)
Air consumption
Pattern width
l/min (cfm)
mm (in)
190 (7.5)
270 (9.5)
220 (8.7)
210 (8.3)
220 (7.8)
240 (9.4)
75 (2.6)
120 (4.7)
145 (5.1)
155 (6.1)
225 (7.9)
160 (6.3)
210 (7.4)
180 (7.1)
145 (5.1)
170 (6.7)
225 (7.9)
175 (6.9)
170 (6.0)
170 (6.7)
75 (2.6)
130 (5.1)
145 (5.1)
170 (6.7)
225 (7.9)
175 (6.9)
210 (7.4)
205 (8.1)
145 (5.1)
180 (7.1)
225 (7.9)
190 (7.5)
170 (6.0)
T
Amb
X
+5°C +40°C
Additional
Ambient
conditions:
Temperature
Any static Electricity should be
discharged and needs to be
diverted to the ground vi a a
conductive air hose not
included.
Flui d needl e
Mark
Mark
/ W1 / 08
08H WIDER1
/ W1 / 10
/ W1 / 13
13 WIDER1
/ W1 / 15
/ W1 / 18
18 WIDER1
Air & fluid
Mass
connection
g (lbs.)
Air
G1/4
(NPS1/4)
290
(0.64)
Fluid
G1/4
(NPS1/4)

Advertisement

loading
Need help?

Need help?

Do you have a question about the Wider 1 and is the answer not in the manual?

Questions and answers

Summary of Contents for Anest Iwata Wider 1

  • Page 1 Improper trade of products outside of designated domestic territories (unauthorized reselling) can result in legal violations, local fines, and penalties. ANEST IWATA CORPORATION assumes no liability for products acquired through unauthorized reselling and in such cases and due to quality control protocols, unauthorized reselling renders the warranty null and void.
  • Page 2: Other Precautions

    ■ Parts list  Description Q’ty Description Q’ty Air cap assy Fluid needle spring assy Nozzleneedle assy Fluid Adj. knob ・ Fluid nozzle Air valve shaft ◆  ◆ ・ Fluid needle Air Adj. assy Needle packing set Trigger assy ◆  Pattern Adj. assy Trigger stud assy Air valve seat assy Brush...
  • Page 3 ・ Only an experienced person who is fully knowledgeable of the equipment should perform maintenance and inspection. ・ Use neutral cleaner: pH value shall be 6 to 8, otherwise could cause corrosion. ・ Only use genuine ANEST IWATA parts for any maintenance or repairs. Step-by-step procedure 1.
  • Page 4 ■ Troubleshooting Spray Pattern Problems Remedies 1. Air enters between fluid nozzle and tapered seat of spray gun body. 1. Remove fluid nozzle to clean seat. If it is damaged, replace nozzle. 2. Air is drawn from fluid needle packing set. 2.
  • Page 5: Residual Risk

    Product model: "Spray gun :WIDER1 / WIDER2" 2019/5/29 Create ANEST IWATA Corporation ※ Be sure to read and understand the instruction manual before using the product. This document is a reference material in the instruction manual and must not be used with only an understanding of the contents of this document.
  • Page 6 Product model: " Spray gun :WIDER1 / WIDER2" 2019/5/29 Create ANEST IWATA Corporation ※ Be sure to read and understand the instruction manual before using the product. This document is a reference material in the instruction manual and must not be used with only an understanding of the contents of this document.